The Proteomics Core Facility offers comprehensive research support within study design, analytical workflows, data processing, statistics, and bioinformatics.
Mass spectrometry–based proteomics enables broad, high‑resolution analysis of proteins from any sample with an available sequence database. It supports applications across basic research, clinical proteomics, biomarker discovery, microbiology, plant biology, and more.
The Proteomics Core Facility has extensive experience preparing diverse sample types, including tissues, cells, organelles, affinity‑purified complexes, and expressed proteins. Equipped with state‑of‑the‑art high‑resolution mass spectrometers, the facility offers comprehensive data analysis using leading search engines (Sequest, Pulsar) and software platforms such as Proteome Discoverer, Byonic, Spectronaut, and MaxQuant.
Poster for download describing technologies and applications
Protein identification
Identification of proteins from a complex mixture (e.g. cell lysate), or verification of a (modified) amino acid sequence from a highly purified protein can be performed by the Proteomics Core Facility.
The proteins are typically cleaved by trypsin into peptides (in-gel, in-solution or bead-based SP3 prep) and analyzed by nano LC MS-MS. The detected peptides are matched against the sequence of the purified protein or against a publicly available protein database as SwissProt or NCBI using Proteome Discoverer. For complex samples an optional off-line fractionation step as High pH liquid chromatography can be included in the workflow to facilitate identification of low abundant proteins and to improve the number of protein identifications.
Samples can be submitted either in-solution, as a protein pellet or a protein band from a gel separation. Avoid the use of detergents as NP40, Triton X100 and Tween in any buffers since their presence significantly interferes with the downstream MS analysis.
Gel cuts are submitted in a tube and covered by 3% acetic acid in ultra-pure water. We prefer Coomassie blue-visible protein bands. In case of silver staining, please use an MS compatible silver staining method (e.g. Pierce Silver Staining for Mass Spectrometry Kit, Thermo #24600).
Poster for download describing technologies and applications
Protein identification
Identification of proteins from a complex mixture (e.g. cell lysate), or verification of a (modified) amino acid sequence from a highly purified protein can be performed by the Proteomics Core Facility.
The proteins are typically cleaved by trypsin into peptides (in-gel, in-solution or bead-based SP3 prep) and analyzed by nano LC MS-MS. The detected peptides are matched against the sequence of the purified protein or against a publicly available protein database as SwissProt or NCBI using Proteome Discoverer. For complex samples an optional off-line fractionation step as High pH liquid chromatography can be included in the workflow to facilitate identification of low abundant proteins and to improve the number of protein identifications.
Samples can be submitted either in-solution, as a protein pellet or a protein band from a gel separation. Avoid the use of detergents as NP40, Triton X100 and Tween in any buffers since their presence significantly interferes with the downstream MS analysis.
Gel cuts are submitted in a tube and covered by 3% acetic acid in ultra-pure water. We prefer Coomassie blue-visible protein bands. In case of silver staining, please use an MS compatible silver staining method (e.g. Pierce Silver Staining for Mass Spectrometry Kit, Thermo #24600).
Relative protein quantification
Global quantitative proteomics is a powerful strategy for unbiased analyses and understanding protein-level changes as well as modification profiles (e.g. phosphorylation) in biopsies, cells, body fluids, or other biological materials. This approach provides critical insights into global protein expression patterns, revealing the molecular mechanisms underlying biological processes and their dynamics.
Isobaric Labelling with Tandem Mass Tags
This chemical labelling approach using Tandem Mass Tags (TMT, Thermo Fisher) provides low variability and very accurate quantification. It allows multiplexing of up to 18 samples in a single analysis, making it suitable for studies involving 2 to 50 samples.
Proteins are commonly purified and digested with trypsin using an adapted SP3 method, based on precipitation of proteins onto Sera-Mag™ SpeedBeads. The clean peptides will be labeling with TMT and pooled into one sample for further handling.
Usually, an off-line fractionation step as High pH liquid chromatography will be included in the workflow reducing sample complexity to facilitate identification of low abundant proteins and to improve the number of protein identifications.
During fragmentation in the mass spectrometer, the Tandem Mass Tags create specific reporter ions, which are used to to relatively quantify the same peptide across different samples.
Using this technique, you can expect to quantify 6,000-8,000 proteins in e.g. human or mouse tissue.
Label-free quantification (LFQ)
The approach does not involve labeling and is accomplished with high sample throughput. Thus, it is suited for large pre-clinical and clinical studies including hundreds of samples, typically from tissue biopsies or blood.
Plasma samples will be processed using the automated P2 enrichment system (Biognosys), providing exceptional quantitative accuracy, proteome depth and reproducibility.
Data-Independent Acquisition (DIA) is based on selection of theoretically all present peptides in an MS scan in and thus enables Label-Free Quantification (LFQ) of many peptides at the same time. This LCMS method does not require labelling, involves very short LCMS gradients and sample preparation can easily be automized, making it ideal for large-scale studies, such as those conducted within clinical precision medicine or pre-clinical studies.
Using LFQ-DIA on tissue, you can expect to quantify 8,000-11,000 proteins in fresh-frozen and 4,000-6,000 proteins in FFPE samples.
Plasma proteomics was been a challenging in the past years due to the high dynamic range hampering identification of more than 500 proteins. Former strategies depleting the most abundant proteins in plasma have suffered from high technical variability. The P2 enrichment platform has recently proven to be highly efficient and reproducible, enabling quantification of 4,500-7,000 plasma proteins depending on the type of disease examined.
Poster for download describing technologies and applications
Protein identification
Identification of proteins from a complex mixture (e.g. cell lysate), or verification of a (modified) amino acid sequence from a highly purified protein can be performed by the Proteomics Core Facility.
The proteins are typically cleaved by trypsin into peptides (in-gel, in-solution or bead-based SP3 prep) and analyzed by nano LC MS-MS. The detected peptides are matched against the sequence of the purified protein or against a publicly available protein database as SwissProt or NCBI using Proteome Discoverer. For complex samples an optional off-line fractionation step as High pH liquid chromatography can be included in the workflow to facilitate identification of low abundant proteins and to improve the number of protein identifications.
Samples can be submitted either in-solution, as a protein pellet or a protein band from a gel separation. Avoid the use of detergents as NP40, Triton X100 and Tween in any buffers since their presence significantly interferes with the downstream MS analysis.
Gel cuts are submitted in a tube and covered by 3% acetic acid in ultra-pure water. We prefer Coomassie blue-visible protein bands. In case of silver staining, please use an MS compatible silver staining method (e.g. Pierce Silver Staining for Mass Spectrometry Kit, Thermo #24600).
Relative protein quantification
Global quantitative proteomics is a powerful strategy for unbiased analyses and understanding protein-level changes as well as modification profiles (e.g. phosphorylation) in biopsies, cells, body fluids, or other biological materials. This approach provides critical insights into global protein expression patterns, revealing the molecular mechanisms underlying biological processes and their dynamics.
Isobaric Labelling with Tandem Mass Tags
This chemical labelling approach using Tandem Mass Tags (TMT, Thermo Fisher) provides low variability and very accurate quantification. It allows multiplexing of up to 18 samples in a single analysis, making it suitable for studies involving 2 to 50 samples.
Proteins are commonly purified and digested with trypsin using an adapted SP3 method, based on precipitation of proteins onto Sera-Mag™ SpeedBeads. The clean peptides will be labeling with TMT and pooled into one sample for further handling.
Usually, an off-line fractionation step as High pH liquid chromatography will be included in the workflow reducing sample complexity to facilitate identification of low abundant proteins and to improve the number of protein identifications.
During fragmentation in the mass spectrometer, the Tandem Mass Tags create specific reporter ions, which are used to to relatively quantify the same peptide across different samples.
Using this technique, you can expect to quantify 6,000-8,000 proteins in e.g. human or mouse tissue.
Label-free quantification (LFQ)
The approach does not involve labeling and is accomplished with high sample throughput. Thus, it is suited for large pre-clinical and clinical studies including hundreds of samples, typically from tissue biopsies or blood.
Plasma samples will be processed using the automated P2 enrichment system (Biognosys), providing exceptional quantitative accuracy, proteome depth and reproducibility.
Data-Independent Acquisition (DIA) is based on selection of theoretically all present peptides in an MS scan in and thus enables Label-Free Quantification (LFQ) of many peptides at the same time. This LCMS method does not require labelling, involves very short LCMS gradients and sample preparation can easily be automized, making it ideal for large-scale studies, such as those conducted within clinical precision medicine or pre-clinical studies.
Using LFQ-DIA on tissue, you can expect to quantify 8,000-11,000 proteins in fresh-frozen and 4,000-6,000 proteins in FFPE samples.
Plasma proteomics was been a challenging in the past years due to the high dynamic range hampering identification of more than 500 proteins. Former strategies depleting the most abundant proteins in plasma have suffered from high technical variability. The P2 enrichment platform has recently proven to be highly efficient and reproducible, enabling quantification of 4,500-7,000 plasma proteins depending on the type of disease examined.
Absolute protein quantification
Targeted proteomics provides absolute quantification of selected proteins using isotopically labeled internal standards, enabling highly sensitive and reproducible measurements. This technique is ideal for biomarker validation on larger sample cohorts.
Isotopically modified peptides with known concentrations are added during the sample preparation and are quantified in parallel with its non-modified counterparts to derive absolute peptide concentration. This targeted LCMS methods are called Single or Parallel Reaction Monitoring (SRM/PRM), highly sensitive and selective mass spectrometry methods.
By using panels from ProteomEdge, hundreds of selected proteins from human samples can be absolutely quantified for biomarker identification, validation and translational studies for clinical applications. Learn more about the available ProteomeEdge panels, like ApoEdge™, LiverEdge, ThromboEdge, ComplementEdge, and DiscoveryEdge™175 on the ProteomEdge web site .
During sample preparation, several recombinant human protein fragments containing heavy isotopes are introduced in the first step, minimizing technical variation. These labeled fragments act as internal protein standards (quantitative recombinant protein standards, qRePS), which are quantified in parallel to their non-labeled endogenous counterparts using Parallel Reaction Monitoring (PRM) LC–MS. Read more about the qRePS technology.
Poster for download describing technologies and applications
Protein identification
Identification of proteins from a complex mixture (e.g. cell lysate), or verification of a (modified) amino acid sequence from a highly purified protein can be performed by the Proteomics Core Facility.
The proteins are typically cleaved by trypsin into peptides (in-gel, in-solution or bead-based SP3 prep) and analyzed by nano LC MS-MS. The detected peptides are matched against the sequence of the purified protein or against a publicly available protein database as SwissProt or NCBI using Proteome Discoverer. For complex samples an optional off-line fractionation step as High pH liquid chromatography can be included in the workflow to facilitate identification of low abundant proteins and to improve the number of protein identifications.
Samples can be submitted either in-solution, as a protein pellet or a protein band from a gel separation. Avoid the use of detergents as NP40, Triton X100 and Tween in any buffers since their presence significantly interferes with the downstream MS analysis.
Gel cuts are submitted in a tube and covered by 3% acetic acid in ultra-pure water. We prefer Coomassie blue-visible protein bands. In case of silver staining, please use an MS compatible silver staining method (e.g. Pierce Silver Staining for Mass Spectrometry Kit, Thermo #24600).
Relative protein quantification
Global quantitative proteomics is a powerful strategy for unbiased analyses and understanding protein-level changes as well as modification profiles (e.g. phosphorylation) in biopsies, cells, body fluids, or other biological materials. This approach provides critical insights into global protein expression patterns, revealing the molecular mechanisms underlying biological processes and their dynamics.
Isobaric Labelling with Tandem Mass Tags
This chemical labelling approach using Tandem Mass Tags (TMT, Thermo Fisher) provides low variability and very accurate quantification. It allows multiplexing of up to 18 samples in a single analysis, making it suitable for studies involving 2 to 50 samples.
Proteins are commonly purified and digested with trypsin using an adapted SP3 method, based on precipitation of proteins onto Sera-Mag™ SpeedBeads. The clean peptides will be labeling with TMT and pooled into one sample for further handling.
Usually, an off-line fractionation step as High pH liquid chromatography will be included in the workflow reducing sample complexity to facilitate identification of low abundant proteins and to improve the number of protein identifications.
During fragmentation in the mass spectrometer, the Tandem Mass Tags create specific reporter ions, which are used to to relatively quantify the same peptide across different samples.
Using this technique, you can expect to quantify 6,000-8,000 proteins in e.g. human or mouse tissue.
Label-free quantification (LFQ)
The approach does not involve labeling and is accomplished with high sample throughput. Thus, it is suited for large pre-clinical and clinical studies including hundreds of samples, typically from tissue biopsies or blood.
Plasma samples will be processed using the automated P2 enrichment system (Biognosys), providing exceptional quantitative accuracy, proteome depth and reproducibility.
Data-Independent Acquisition (DIA) is based on selection of theoretically all present peptides in an MS scan in and thus enables Label-Free Quantification (LFQ) of many peptides at the same time. This LCMS method does not require labelling, involves very short LCMS gradients and sample preparation can easily be automized, making it ideal for large-scale studies, such as those conducted within clinical precision medicine or pre-clinical studies.
Using LFQ-DIA on tissue, you can expect to quantify 8,000-11,000 proteins in fresh-frozen and 4,000-6,000 proteins in FFPE samples.
Plasma proteomics was been a challenging in the past years due to the high dynamic range hampering identification of more than 500 proteins. Former strategies depleting the most abundant proteins in plasma have suffered from high technical variability. The P2 enrichment platform has recently proven to be highly efficient and reproducible, enabling quantification of 4,500-7,000 plasma proteins depending on the type of disease examined.
Absolute protein quantification
Targeted proteomics provides absolute quantification of selected proteins using isotopically labeled internal standards, enabling highly sensitive and reproducible measurements. This technique is ideal for biomarker validation on larger sample cohorts.
Isotopically modified peptides with known concentrations are added during the sample preparation and are quantified in parallel with its non-modified counterparts to derive absolute peptide concentration. This targeted LCMS methods are called Single or Parallel Reaction Monitoring (SRM/PRM), highly sensitive and selective mass spectrometry methods.
By using panels from ProteomEdge, hundreds of selected proteins from human samples can be absolutely quantified for biomarker identification, validation and translational studies for clinical applications. Learn more about the available ProteomeEdge panels, like ApoEdge™, LiverEdge, ThromboEdge, ComplementEdge, and DiscoveryEdge™175 on the ProteomEdge web site .
During sample preparation, several recombinant human protein fragments containing heavy isotopes are introduced in the first step, minimizing technical variation. These labeled fragments act as internal protein standards (quantitative recombinant protein standards, qRePS), which are quantified in parallel to their non-labeled endogenous counterparts using Parallel Reaction Monitoring (PRM) LC–MS. Read more about the qRePS technology.
Post-translational modifications
Protein post-translational modifications (PTMs) are chemical modifications that regulate cellular activity and influence the molecular mechanisms of biological processes and disease states. The main challenge studying PTMs is that they are low abundant. PTMs of purified proteins or a highly expressed proteins can be characterised by mass spectrometry directly, while PTMs in complex samples have to be enriched for prior to the MS-analysis.
Glycosylation
Protein glycosylation is one of the most frequent and the most complex post-translational modification regulating cell communication, protein stability and immunity.
Glycobiosynthesis is a non-template driven process, where complex structures (branched and linear) are produced from monosaccharide building blocks by multiple and competitive enzymatic actions. This complexity of the glycobiosynthesis presents an analytical challenge for studies of protein glycosylation.
Due to the structural complexity and the diversity of glycans, protein glycosylation studies are traditionally carried out on the released glycans. The analysis of released glycans (glycomics) provides detailed quantitative and structural glycan data, however, it lacks their protein site-specific information and glycoproteomics should be applied for studies that require characterization of the glycans on the proteome level.
Analogous to proteomics, glycoproteomics is based on advanced Mass Spectrometry technologies optimized for either global or directed analysis of glycoproteins in biological samples. Depending on the selected methodologies, glycoproteomics is capable to provide:
identification and quantification of the proteins carrying glycosylation
identification of the glycosylation sites and site occupancies
site-specific characterization of the glycan structures (monosaccharide compositions and micro heterogeneity)
Protein glycosylation studies often demand a complex design and addressing even one of the above listed questions would frequently require application of multiple advanced technologies for sample preparation and analysis as well as an in-depth knowledge of systems biology and medicine. Therefore, we encourage you to come and discuss with us about your glycoproteomic projects to ensure optimal design in respect to the available material and your biological question.
Glycoproteomics has been identified as an important research field and is currently supported by the national BioMS infrastructure (www.bioms.se) as well as SciLifeLab (www.scilifelab.se).
Phosphorylation
Phosphorylation is also one of the most common post-translational modification. Cells tightly control phosphorylation of proteins by an interplay beweeen kinases and phosphatases, creating a fast, powerful, and transient mechanism adapting cellular processes in response to stimuli.
Phosphoproteomics is the study of changes in the protein phosphorylation pattern due to different treatments or conditions. Quantification of phosphorylation sites among different conditions is often accomplished using labeling with isobaric tags (see relative proteomics analysis, TMT). The number of quantified peptides depends mainly on the cellular response and tissue type, but can cover 10,000-12,000 different phosphopeptides.
Especially the treatment and harvest of samples for phosphoproteomics experiments require attention; therefore please contact the Proteomics Core Facility already during study design.
Phosphoprotein samples are lysed in the presence of phosphatase inhibitors and digested with trypsin. The resulting peptides are labeled with different versions of isobaric tags, and combined into one sample. A small aliquot is used for global proteomics in order to check the protein level background, whereas the majority is subjected to phosphopeptide enrichment. Typically, (phospho)peptides originating from whole cell lysates are pre-fractionated to reduce complexity. Phosphorylation sites are detected by their additional mass of 80 Da on the modified amino acid. Quantification is performed on TMT reporter ions of the isobaric tags created during fragmentation in the mass spectrometer.
Other modifications
Any modification of proteins can be studied as long as the exact composition of the modification is known. The mass shift of the modification is entered manually into the database and used in the database matching. Common other post-translational modifications are ubiquitination, methylation and acetylation. In addition, probe-specific binding to a target protein can be examined and validated using LCMS.
Poster for download describing technologies and applications
Protein identification
Identification of proteins from a complex mixture (e.g. cell lysate), or verification of a (modified) amino acid sequence from a highly purified protein can be performed by the Proteomics Core Facility.
The proteins are typically cleaved by trypsin into peptides (in-gel, in-solution or bead-based SP3 prep) and analyzed by nano LC MS-MS. The detected peptides are matched against the sequence of the purified protein or against a publicly available protein database as SwissProt or NCBI using Proteome Discoverer. For complex samples an optional off-line fractionation step as High pH liquid chromatography can be included in the workflow to facilitate identification of low abundant proteins and to improve the number of protein identifications.
Samples can be submitted either in-solution, as a protein pellet or a protein band from a gel separation. Avoid the use of detergents as NP40, Triton X100 and Tween in any buffers since their presence significantly interferes with the downstream MS analysis.
Gel cuts are submitted in a tube and covered by 3% acetic acid in ultra-pure water. We prefer Coomassie blue-visible protein bands. In case of silver staining, please use an MS compatible silver staining method (e.g. Pierce Silver Staining for Mass Spectrometry Kit, Thermo #24600).
Relative protein quantification
Global quantitative proteomics is a powerful strategy for unbiased analyses and understanding protein-level changes as well as modification profiles (e.g. phosphorylation) in biopsies, cells, body fluids, or other biological materials. This approach provides critical insights into global protein expression patterns, revealing the molecular mechanisms underlying biological processes and their dynamics.
Isobaric Labelling with Tandem Mass Tags
This chemical labelling approach using Tandem Mass Tags (TMT, Thermo Fisher) provides low variability and very accurate quantification. It allows multiplexing of up to 18 samples in a single analysis, making it suitable for studies involving 2 to 50 samples.
Proteins are commonly purified and digested with trypsin using an adapted SP3 method, based on precipitation of proteins onto Sera-Mag™ SpeedBeads. The clean peptides will be labeling with TMT and pooled into one sample for further handling.
Usually, an off-line fractionation step as High pH liquid chromatography will be included in the workflow reducing sample complexity to facilitate identification of low abundant proteins and to improve the number of protein identifications.
During fragmentation in the mass spectrometer, the Tandem Mass Tags create specific reporter ions, which are used to to relatively quantify the same peptide across different samples.
Using this technique, you can expect to quantify 6,000-8,000 proteins in e.g. human or mouse tissue.
Label-free quantification (LFQ)
The approach does not involve labeling and is accomplished with high sample throughput. Thus, it is suited for large pre-clinical and clinical studies including hundreds of samples, typically from tissue biopsies or blood.
Plasma samples will be processed using the automated P2 enrichment system (Biognosys), providing exceptional quantitative accuracy, proteome depth and reproducibility.
Data-Independent Acquisition (DIA) is based on selection of theoretically all present peptides in an MS scan in and thus enables Label-Free Quantification (LFQ) of many peptides at the same time. This LCMS method does not require labelling, involves very short LCMS gradients and sample preparation can easily be automized, making it ideal for large-scale studies, such as those conducted within clinical precision medicine or pre-clinical studies.
Using LFQ-DIA on tissue, you can expect to quantify 8,000-11,000 proteins in fresh-frozen and 4,000-6,000 proteins in FFPE samples.
Plasma proteomics was been a challenging in the past years due to the high dynamic range hampering identification of more than 500 proteins. Former strategies depleting the most abundant proteins in plasma have suffered from high technical variability. The P2 enrichment platform has recently proven to be highly efficient and reproducible, enabling quantification of 4,500-7,000 plasma proteins depending on the type of disease examined.
Absolute protein quantification
Targeted proteomics provides absolute quantification of selected proteins using isotopically labeled internal standards, enabling highly sensitive and reproducible measurements. This technique is ideal for biomarker validation on larger sample cohorts.
Isotopically modified peptides with known concentrations are added during the sample preparation and are quantified in parallel with its non-modified counterparts to derive absolute peptide concentration. This targeted LCMS methods are called Single or Parallel Reaction Monitoring (SRM/PRM), highly sensitive and selective mass spectrometry methods.
By using panels from ProteomEdge, hundreds of selected proteins from human samples can be absolutely quantified for biomarker identification, validation and translational studies for clinical applications. Learn more about the available ProteomeEdge panels, like ApoEdge™, LiverEdge, ThromboEdge, ComplementEdge, and DiscoveryEdge™175 on the ProteomEdge web site .
During sample preparation, several recombinant human protein fragments containing heavy isotopes are introduced in the first step, minimizing technical variation. These labeled fragments act as internal protein standards (quantitative recombinant protein standards, qRePS), which are quantified in parallel to their non-labeled endogenous counterparts using Parallel Reaction Monitoring (PRM) LC–MS. Read more about the qRePS technology.
Post-translational modifications
Protein post-translational modifications (PTMs) are chemical modifications that regulate cellular activity and influence the molecular mechanisms of biological processes and disease states. The main challenge studying PTMs is that they are low abundant. PTMs of purified proteins or a highly expressed proteins can be characterised by mass spectrometry directly, while PTMs in complex samples have to be enriched for prior to the MS-analysis.
Glycosylation
Protein glycosylation is one of the most frequent and the most complex post-translational modification regulating cell communication, protein stability and immunity.
Glycobiosynthesis is a non-template driven process, where complex structures (branched and linear) are produced from monosaccharide building blocks by multiple and competitive enzymatic actions. This complexity of the glycobiosynthesis presents an analytical challenge for studies of protein glycosylation.
Due to the structural complexity and the diversity of glycans, protein glycosylation studies are traditionally carried out on the released glycans. The analysis of released glycans (glycomics) provides detailed quantitative and structural glycan data, however, it lacks their protein site-specific information and glycoproteomics should be applied for studies that require characterization of the glycans on the proteome level.
Analogous to proteomics, glycoproteomics is based on advanced Mass Spectrometry technologies optimized for either global or directed analysis of glycoproteins in biological samples. Depending on the selected methodologies, glycoproteomics is capable to provide:
identification and quantification of the proteins carrying glycosylation
identification of the glycosylation sites and site occupancies
site-specific characterization of the glycan structures (monosaccharide compositions and micro heterogeneity)
Protein glycosylation studies often demand a complex design and addressing even one of the above listed questions would frequently require application of multiple advanced technologies for sample preparation and analysis as well as an in-depth knowledge of systems biology and medicine. Therefore, we encourage you to come and discuss with us about your glycoproteomic projects to ensure optimal design in respect to the available material and your biological question.
Glycoproteomics has been identified as an important research field and is currently supported by the national BioMS infrastructure (www.bioms.se) as well as SciLifeLab (www.scilifelab.se).
Phosphorylation
Phosphorylation is also one of the most common post-translational modification. Cells tightly control phosphorylation of proteins by an interplay beweeen kinases and phosphatases, creating a fast, powerful, and transient mechanism adapting cellular processes in response to stimuli.
Phosphoproteomics is the study of changes in the protein phosphorylation pattern due to different treatments or conditions. Quantification of phosphorylation sites among different conditions is often accomplished using labeling with isobaric tags (see relative proteomics analysis, TMT). The number of quantified peptides depends mainly on the cellular response and tissue type, but can cover 10,000-12,000 different phosphopeptides.
Especially the treatment and harvest of samples for phosphoproteomics experiments require attention; therefore please contact the Proteomics Core Facility already during study design.
Phosphoprotein samples are lysed in the presence of phosphatase inhibitors and digested with trypsin. The resulting peptides are labeled with different versions of isobaric tags, and combined into one sample. A small aliquot is used for global proteomics in order to check the protein level background, whereas the majority is subjected to phosphopeptide enrichment. Typically, (phospho)peptides originating from whole cell lysates are pre-fractionated to reduce complexity. Phosphorylation sites are detected by their additional mass of 80 Da on the modified amino acid. Quantification is performed on TMT reporter ions of the isobaric tags created during fragmentation in the mass spectrometer.
Other modifications
Any modification of proteins can be studied as long as the exact composition of the modification is known. The mass shift of the modification is entered manually into the database and used in the database matching. Common other post-translational modifications are ubiquitination, methylation and acetylation. In addition, probe-specific binding to a target protein can be examined and validated using LCMS.
Interaction or network analyses
Proteins rarely act alone, and their functions are regulated by interacting partners. Samples from immunoprecipitations and pull-downs will be commonly processed using the relative quantification workflow involving TMT labeling.
Immunoprecipitations are performed using antibodies for protein-of-interest isolation; whereas affinity purifications and pull-down experiments are done using a tagged bait like RNA or peptides. The researcher is responsible for the IP/pull-down optimization and procedure and that it has been performed in a MS-compatible way.
There are several critical sample preparation steps that affect the downstream MS-analysis and they must be considered before performing the experiment. Please contact the Core Facility to discuss the project prior to sample preparation.
Optimization of protocol Detailed protocols and guidance for setting up an IP/pull down experiment are provided by the manufacturer of the IP beads. In order to optimize experimental conditions, work initially on a small scale. For the final MS-analysis it is important to do a large scale preparation.
We recommend that you optimize your IP by monitoring the efficiency with Western blotting (WB) against your protein. To determine the quality of IP/pull-down and amount of protein in the sample (protein of interest, background proteins and antibody) SDS-PAGE and Coomassie staining are required. Image of WB and Coomassie-stained gel are send together with the sample submission form, when you hand-in the samples to the Proteomics Core Facility.
To reduce the background elute using mild conditions. SDS in elution buffer will give massive background, since non-specifically bound proteins will be eluted together with target proteins. In IP experiments, it is important to cross-link the antibody to the beads. Both background proteins and antibody in the eluate will obstruct identification of the proteins in the complex. PEG-containing detergents as NP40, TritonX100, and Tween should be avoided or used in very low concentrations.
At PCF, the samples are usually prepared using the bead-based SP3 method. Peptides originating from trypsin digest will then be analyzed with nanoLC MS/MS followed by matching against a publicly available protein database as SwissProt using Proteome Discoverer for protein identification. For data analyses, protein-protein interaction (PPIs) databases provide known and predicted protein-protein interaction networks.
Poster for download describing technologies and applications
Protein identification
Identification of proteins from a complex mixture (e.g. cell lysate), or verification of a (modified) amino acid sequence from a highly purified protein can be performed by the Proteomics Core Facility.
The proteins are typically cleaved by trypsin into peptides (in-gel, in-solution or bead-based SP3 prep) and analyzed by nano LC MS-MS. The detected peptides are matched against the sequence of the purified protein or against a publicly available protein database as SwissProt or NCBI using Proteome Discoverer. For complex samples an optional off-line fractionation step as High pH liquid chromatography can be included in the workflow to facilitate identification of low abundant proteins and to improve the number of protein identifications.
Samples can be submitted either in-solution, as a protein pellet or a protein band from a gel separation. Avoid the use of detergents as NP40, Triton X100 and Tween in any buffers since their presence significantly interferes with the downstream MS analysis.
Gel cuts are submitted in a tube and covered by 3% acetic acid in ultra-pure water. We prefer Coomassie blue-visible protein bands. In case of silver staining, please use an MS compatible silver staining method (e.g. Pierce Silver Staining for Mass Spectrometry Kit, Thermo #24600).
Relative protein quantification
Global quantitative proteomics is a powerful strategy for unbiased analyses and understanding protein-level changes as well as modification profiles (e.g. phosphorylation) in biopsies, cells, body fluids, or other biological materials. This approach provides critical insights into global protein expression patterns, revealing the molecular mechanisms underlying biological processes and their dynamics.
Isobaric Labelling with Tandem Mass Tags
This chemical labelling approach using Tandem Mass Tags (TMT, Thermo Fisher) provides low variability and very accurate quantification. It allows multiplexing of up to 18 samples in a single analysis, making it suitable for studies involving 2 to 50 samples.
Proteins are commonly purified and digested with trypsin using an adapted SP3 method, based on precipitation of proteins onto Sera-Mag™ SpeedBeads. The clean peptides will be labeling with TMT and pooled into one sample for further handling.
Usually, an off-line fractionation step as High pH liquid chromatography will be included in the workflow reducing sample complexity to facilitate identification of low abundant proteins and to improve the number of protein identifications.
During fragmentation in the mass spectrometer, the Tandem Mass Tags create specific reporter ions, which are used to to relatively quantify the same peptide across different samples.
Using this technique, you can expect to quantify 6,000-8,000 proteins in e.g. human or mouse tissue.
Label-free quantification (LFQ)
The approach does not involve labeling and is accomplished with high sample throughput. Thus, it is suited for large pre-clinical and clinical studies including hundreds of samples, typically from tissue biopsies or blood.
Plasma samples will be processed using the automated P2 enrichment system (Biognosys), providing exceptional quantitative accuracy, proteome depth and reproducibility.
Data-Independent Acquisition (DIA) is based on selection of theoretically all present peptides in an MS scan in and thus enables Label-Free Quantification (LFQ) of many peptides at the same time. This LCMS method does not require labelling, involves very short LCMS gradients and sample preparation can easily be automized, making it ideal for large-scale studies, such as those conducted within clinical precision medicine or pre-clinical studies.
Using LFQ-DIA on tissue, you can expect to quantify 8,000-11,000 proteins in fresh-frozen and 4,000-6,000 proteins in FFPE samples.
Plasma proteomics was been a challenging in the past years due to the high dynamic range hampering identification of more than 500 proteins. Former strategies depleting the most abundant proteins in plasma have suffered from high technical variability. The P2 enrichment platform has recently proven to be highly efficient and reproducible, enabling quantification of 4,500-7,000 plasma proteins depending on the type of disease examined.
Absolute protein quantification
Targeted proteomics provides absolute quantification of selected proteins using isotopically labeled internal standards, enabling highly sensitive and reproducible measurements. This technique is ideal for biomarker validation on larger sample cohorts.
Isotopically modified peptides with known concentrations are added during the sample preparation and are quantified in parallel with its non-modified counterparts to derive absolute peptide concentration. This targeted LCMS methods are called Single or Parallel Reaction Monitoring (SRM/PRM), highly sensitive and selective mass spectrometry methods.
By using panels from ProteomEdge, hundreds of selected proteins from human samples can be absolutely quantified for biomarker identification, validation and translational studies for clinical applications. Learn more about the available ProteomeEdge panels, like ApoEdge™, LiverEdge, ThromboEdge, ComplementEdge, and DiscoveryEdge™175 on the ProteomEdge web site .
During sample preparation, several recombinant human protein fragments containing heavy isotopes are introduced in the first step, minimizing technical variation. These labeled fragments act as internal protein standards (quantitative recombinant protein standards, qRePS), which are quantified in parallel to their non-labeled endogenous counterparts using Parallel Reaction Monitoring (PRM) LC–MS. Read more about the qRePS technology.
Post-translational modifications
Protein post-translational modifications (PTMs) are chemical modifications that regulate cellular activity and influence the molecular mechanisms of biological processes and disease states. The main challenge studying PTMs is that they are low abundant. PTMs of purified proteins or a highly expressed proteins can be characterised by mass spectrometry directly, while PTMs in complex samples have to be enriched for prior to the MS-analysis.
Glycosylation
Protein glycosylation is one of the most frequent and the most complex post-translational modification regulating cell communication, protein stability and immunity.
Glycobiosynthesis is a non-template driven process, where complex structures (branched and linear) are produced from monosaccharide building blocks by multiple and competitive enzymatic actions. This complexity of the glycobiosynthesis presents an analytical challenge for studies of protein glycosylation.
Due to the structural complexity and the diversity of glycans, protein glycosylation studies are traditionally carried out on the released glycans. The analysis of released glycans (glycomics) provides detailed quantitative and structural glycan data, however, it lacks their protein site-specific information and glycoproteomics should be applied for studies that require characterization of the glycans on the proteome level.
Analogous to proteomics, glycoproteomics is based on advanced Mass Spectrometry technologies optimized for either global or directed analysis of glycoproteins in biological samples. Depending on the selected methodologies, glycoproteomics is capable to provide:
identification and quantification of the proteins carrying glycosylation
identification of the glycosylation sites and site occupancies
site-specific characterization of the glycan structures (monosaccharide compositions and micro heterogeneity)
Protein glycosylation studies often demand a complex design and addressing even one of the above listed questions would frequently require application of multiple advanced technologies for sample preparation and analysis as well as an in-depth knowledge of systems biology and medicine. Therefore, we encourage you to come and discuss with us about your glycoproteomic projects to ensure optimal design in respect to the available material and your biological question.
Glycoproteomics has been identified as an important research field and is currently supported by the national BioMS infrastructure (www.bioms.se) as well as SciLifeLab (www.scilifelab.se).
Phosphorylation
Phosphorylation is also one of the most common post-translational modification. Cells tightly control phosphorylation of proteins by an interplay beweeen kinases and phosphatases, creating a fast, powerful, and transient mechanism adapting cellular processes in response to stimuli.
Phosphoproteomics is the study of changes in the protein phosphorylation pattern due to different treatments or conditions. Quantification of phosphorylation sites among different conditions is often accomplished using labeling with isobaric tags (see relative proteomics analysis, TMT). The number of quantified peptides depends mainly on the cellular response and tissue type, but can cover 10,000-12,000 different phosphopeptides.
Especially the treatment and harvest of samples for phosphoproteomics experiments require attention; therefore please contact the Proteomics Core Facility already during study design.
Phosphoprotein samples are lysed in the presence of phosphatase inhibitors and digested with trypsin. The resulting peptides are labeled with different versions of isobaric tags, and combined into one sample. A small aliquot is used for global proteomics in order to check the protein level background, whereas the majority is subjected to phosphopeptide enrichment. Typically, (phospho)peptides originating from whole cell lysates are pre-fractionated to reduce complexity. Phosphorylation sites are detected by their additional mass of 80 Da on the modified amino acid. Quantification is performed on TMT reporter ions of the isobaric tags created during fragmentation in the mass spectrometer.
Other modifications
Any modification of proteins can be studied as long as the exact composition of the modification is known. The mass shift of the modification is entered manually into the database and used in the database matching. Common other post-translational modifications are ubiquitination, methylation and acetylation. In addition, probe-specific binding to a target protein can be examined and validated using LCMS.
Interaction or network analyses
Proteins rarely act alone, and their functions are regulated by interacting partners. Samples from immunoprecipitations and pull-downs will be commonly processed using the relative quantification workflow involving TMT labeling.
Immunoprecipitations are performed using antibodies for protein-of-interest isolation; whereas affinity purifications and pull-down experiments are done using a tagged bait like RNA or peptides. The researcher is responsible for the IP/pull-down optimization and procedure and that it has been performed in a MS-compatible way.
There are several critical sample preparation steps that affect the downstream MS-analysis and they must be considered before performing the experiment. Please contact the Core Facility to discuss the project prior to sample preparation.
Optimization of protocol Detailed protocols and guidance for setting up an IP/pull down experiment are provided by the manufacturer of the IP beads. In order to optimize experimental conditions, work initially on a small scale. For the final MS-analysis it is important to do a large scale preparation.
We recommend that you optimize your IP by monitoring the efficiency with Western blotting (WB) against your protein. To determine the quality of IP/pull-down and amount of protein in the sample (protein of interest, background proteins and antibody) SDS-PAGE and Coomassie staining are required. Image of WB and Coomassie-stained gel are send together with the sample submission form, when you hand-in the samples to the Proteomics Core Facility.
To reduce the background elute using mild conditions. SDS in elution buffer will give massive background, since non-specifically bound proteins will be eluted together with target proteins. In IP experiments, it is important to cross-link the antibody to the beads. Both background proteins and antibody in the eluate will obstruct identification of the proteins in the complex. PEG-containing detergents as NP40, TritonX100, and Tween should be avoided or used in very low concentrations.
At PCF, the samples are usually prepared using the bead-based SP3 method. Peptides originating from trypsin digest will then be analyzed with nanoLC MS/MS followed by matching against a publicly available protein database as SwissProt using Proteome Discoverer for protein identification. For data analyses, protein-protein interaction (PPIs) databases provide known and predicted protein-protein interaction networks.
Equipment
Automated sample preparation
Beckman Coulter Biomek i7
Thermo KingFisher Apex
Cellenion CellenONE
Chromatographic systems
online: Thermo Easy nLC1200 systems
online: Evosep One/Eno nLC systems
online: Thermo Vanquish Neo systems
offline: high pH UPLC fractionation: Thermo Dionex Ultimate 3000