Avanta versus Swanson silicone implants in the MCP joint--a prospective, randomized comparison of 30 patients followed for 2 years

Artikel i vetenskaplig tidskrift
Författare Karin Möller
Christer Sollerman
Mats Geijer
P Kopylov
M Tagil
Publicerad i J Hand Surg [Br]
Volym 30
Nummer/häfte 1
Sidor 8-13
ISSN 0266-7681 (Print)
Publiceringsår 2005
Publicerad vid Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi
Institutionen för de kirurgiska disciplinerna, Avdelningen för kirurgi
Institutionen för särskilda specialiteter, Avdelningen för radiologi
Sidor 8-13
Språk en
Länkar dx.doi.org/10.1016/j.jhsb.2004.09.0...
Ämnesord Adult, Aged, Arthritis, Psoriatic/physiopathology/surgery, Arthritis, Rheumatoid/physiopathology/*surgery, Arthroplasty, Replacement/*instrumentation, Biocompatible Materials/therapeutic use, Female, Follow-Up Studies, Hand Strength, Humans, *Joint Prosthesis, Male, Metacarpophalangeal Joint/*surgery, Middle Aged, Prospective Studies, Prosthesis Failure, Range of Motion, Articular, Recovery of Function, Silicones/therapeutic use, Treatment Outcome
Ämneskategorier Medicin och Hälsovetenskap, Reumatologi och inflammation, Handkirurgi

Sammanfattning

The results of Swanson and Avanta metacarpophalangeal joint arthroplasties in rheumatoid patients were compared in a prospective, randomized study of 30 patients (120 implants). At 2-year follow-up, grip strength was measured, hand function was assessed with the Sollerman test and the subjective outcome was determined with visual analogue scores. With both implants ulnar deviation and flexion deformities decreased, and there was no difference between the groups. The increase in range of motion was 7 degrees greater with Avanta implants than with Swanson implants. Grip strength and hand function were unaltered but the visual analogue scales showed decreased pain levels and subjective improvements in hand function, grip strength and cosmesis. Twenty-four of 30 patients were satisfied. Fracture of the silicone spacer occurred with 12 Avanta (20%) and eight Swanson implants (13%), with a higher fracture frequency in men.