Till sidans topp

Sidansvarig: Webbredaktion
Sidan uppdaterades: 2012-09-11 15:12

Tipsa en vän
Utskriftsversion

Immediate loading of one … - Göteborgs universitet Till startsida
Webbkarta
Till innehåll Läs mer om hur kakor används på gu.se

Immediate loading of one (fixed-on-1) versus two (fixed-on-2) implants placed flapless supporting mandibular screw-retained cross-arch fixed prostheses: 10-month results from an explanatory randomised controlled trial

Artikel i vetenskaplig tidskrift
Författare G. Cannizzaro
P. Viola
D. R. Ippolito
Marco Esposito
Publicerad i European Journal of Oral Implantology
Volym 12
Nummer/häfte 1
Sidor 89-102
ISSN 1756-2406
Publiceringsår 2019
Publicerad vid Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap
Sidor 89-102
Språk en
Ämnesord dental implants, flapless, fixed-on-1, fixed-on-2, immediate loading, randomised controlled trial, 4 endosseous implants, 6-month follow-up, single implants, overdentures, surgery, system, torque, Dentistry, Oral Surgery & Medicine
Ämneskategorier Biomaterial

Sammanfattning

Purpose: To evaluate the outcome of one (fixed-on-1, Fo1) versus two (fixed-on-2, Fo2) implants placed flapless in fully edentulous mandibles and immediately restored with metal-resin screwretained cross-arch prostheses. Materials and methods: Twenty patients with edentulous or to be rendered edentulous mandibles were randomised to the Fo1 group (10 patients who received three intraforaminal implants but only the mesial implant was actually loaded) and to the Fo2 group (10 patients who received two intraforaminal implants) according to a parallel-group design. To be immediately loaded implants had to be inserted with a minimum torque of 60 Ncm. Outcome measures were prosthesis and implant failures, complications and patient satisfaction for function and aesthetics evaluated up to 10 months post-loading. Results: Flaps were raised in three patients of the Fo1 group and one of the Fo2 group. Two prostheses in each group were delayed loaded at 2 and 3 months, because implants could not be inserted with a torque superior to 60 Ncm. Patients of the Fo2 group received prostheses with 12 teeth whereas Fo1 patients with 8 or 10 teeth. Ten months after loading no drop-out or implant failure occurred, but one Fo2 prosthesis had to be remade because the patient complained it was too short (risk difference = 0.1; 95% CI: -0.19 to 0.40; Fisher's exact test P = 1.000). Three patients were affected by complications in each group (risk difference = 0.0; 95% CI: -0.359 to 0.359; Fisher's exact test; P. 1.000). There were no statistically significant differences for prosthetic failures and complications between groups. Four months after loading, patients of the Fo1 group were less satisfied for function than those of the Fo2 group (difference between the medians [Hodges-Lehmann estimation] =1; 95% CI: 0 to 2; P = 0.043). No differences were observed for aesthetics (difference between the medians [Hodges-Lehmann estimation] = 0; 95% CI: -1 to 0; P = 0.481), and two Fo1 patients would not undergo the same procedure again (difference in proportions: 0.2; 95% CI: -0.11 to 0.51; P = 0.474). Conclusions: Preliminary results suggest that immediately loaded cross-arch screw-retained fixed prostheses with 8 to 10 teeth can be supported by only one dental implant at least up to 10 months post-loading; however, the clinical application and usefulness of such a procedure remains questionable.

Sidansvarig: Webbredaktion|Sidan uppdaterades: 2012-09-11
Dela:

På Göteborgs universitet använder vi kakor (cookies) för att webbplatsen ska fungera på ett bra sätt för dig. Genom att surfa vidare godkänner du att vi använder kakor.  Vad är kakor?