Interleukin-6 measured using the automated electrochemiluminescence immunoassay method for the identification of intra-amniotic inflammation in preterm prelabor rupture of membranes.

Artikel i vetenskaplig tidskrift
Författare Ivana Musilova
Ctirad Andrys
Magdalena Holeckova
Veronika Kolarova
Lenka Pliskova
Marcela Drahosova
Radka Bolehovska
Radovan Pilka
Karel Huml
Teresa Cobo
Bo Jacobsson
Marian Kacerovsky
Publicerad i The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians
Sidor 1-131
ISSN 1476-4954
Publiceringsår 2018
Publicerad vid Institutionen för kliniska vetenskaper, Avdelningen för obstetrik och gynekologi
Sidor 1-131
Språk en
Länkar dx.doi.org/10.1080/14767058.2018.15...
www.ncbi.nlm.nih.gov/entrez/query.f...
Ämneskategorier Klinisk medicin, Reproduktionsmedicin och gynekologi, Obstetrik och kvinnosjukdomar, Obstetrik och gynekologi

Sammanfattning

We aimed to compare the amniotic fluid interleukin (IL)-6 concentrations measured using the automated electrochemiluminescence immunoassay method and ELISA, and to establish an IL-6 concentration cut-off value for intra-amniotic inflammation (IAI) in preterm prelabor rupture of membranes (PPROM), which can be used in the automated electrochemiluminescence immunoassay method.A total of 120 women with PPROM were included in this study. Amniotic fluid samples were obtained via transabdominal amniocentesis. IL-6 concentrations were assessed using both the automated electrochemiluminescence immunoassay method and ELISA, the current gold standard. IAI was defined as an amniotic fluid IL-6 concentration of ≥ 2600 pg/mL measured using ELISA.A correlation between both assays was found (Spearman's rho = 0.97; p < 0.0001). Based on the receiver-operating characteristic curve for the identification of IAI (area under the curve = 0.99), a cut-off value of ≥ 3000 pg/mL was selected for the automated electrochemiluminescence immunoassay method with a sensitivity of 88%, specificity of 99%, positive predictive value of 97%, negative predictive value of 96%, and likelihood ratio of 76.