Till sidans topp

Sidansvarig: Webbredaktion
Sidan uppdaterades: 2012-09-11 15:12

Tipsa en vän
Utskriftsversion

Critical considerations o… - Göteborgs universitet Till startsida
Webbkarta
Till innehåll Läs mer om hur kakor används på gu.se

Critical considerations on load-to-failure test for monolithic zirconia molar crowns

Artikel i vetenskaplig tidskrift
Författare K. Nakamura
S. Ankyu
F. Nilsson
T. Kanno
Y. Niwano
P. V. von Steyern
Ulf Örtengren
Publicerad i Journal of the Mechanical Behavior of Biomedical Materials
Volym 87
Sidor 180-189
ISSN 1751-6161
Publiceringsår 2018
Publicerad vid Institutionen för odontologi
Sidor 180-189
Språk en
Länkar dx.doi.org/10.1016/j.jmbbm.2018.07....
Ämnesord Monolithic zirconia crowns, Fractography, Fracture resistance, Thermal fatigue, Mechanical fatigue, CAD/CAM, Finite element modeling, all-ceramic crowns, fracture-resistance, in-vitro, dental restorations, single crowns, thickness, strength, metaanalysis, simulation, porcelain, Engineering, Materials Science
Ämneskategorier Odontologi

Sammanfattning

Application of monolithic zirconia crowns (MZCs) with reduced thickness to the molar region has been proposed, but potential complications have yet to be fully evaluated in laboratory tests. The present study aimed to develop a clinically relevant load-to-failure test in combination with fatigue treatments involving thermal and mechanical cycling (TC and MC) to evaluate the fracture resistance of molar MZCs. MZCs with a minimal thickness of 0.5 mm were bonded to dies made of resin-based composite (RBC), epoxy resin (EP), or polyoxymethylene-copolymer (POM-C). The samples were either untreated (UT) or subjected to TC (5-55 degrees C for 1 x 10(5) cycles) and MC (300 N for 2.4 x 10(6) cycles). The stress generated by TC and MC was simulated by finite element modeling. The load-to-failure test was performed using an inverse V-shaped two-plane indenter and was followed by fractographic analysis. The median values of fracture load for MZC/RBC and MZC/EP in the TC group were significantly lower than those in the UT group. MC also decreased the median value of fracture load for MZC/RBC significantly, but not that for MZC/EP and MZC/POM-C. Fractography revealed that the fracture started in the cervical area in all groups, which is similar to clinically failed crowns. The simulation confirmed stress concentration at the cervical area in both TC and MC groups. The present study suggests that the load-to-failure test using a two-plane indenter could induce clinically relevant fracture of MZCs, the vulnerability of the MZCs depends largely on the die material employed, and MZCs are more likely to be damaged by thermal fatigue than mechanical fatigue.

Sidansvarig: Webbredaktion|Sidan uppdaterades: 2012-09-11
Dela:

På Göteborgs universitet använder vi kakor (cookies) för att webbplatsen ska fungera på ett bra sätt för dig. Genom att surfa vidare godkänner du att vi använder kakor.  Vad är kakor?