Till sidans topp

Sidansvarig: Webbredaktion
Sidan uppdaterades: 2012-09-11 15:12

Tipsa en vän
Utskriftsversion

A Treatment-Response Inde… - Göteborgs universitet Till startsida
Webbkarta
Till innehåll Läs mer om hur kakor används på gu.se

A Treatment-Response Index From Wearable Sensors for Quantifying Parkinson's Disease Motor States

Artikel i vetenskaplig tidskrift
Författare I. Thomas
J. Westin
M. Alam
Filip Bergquist
D. Nyholm
M. Senek
M. Memedi
Publicerad i Ieee Journal of Biomedical and Health Informatics
Volym 22
Nummer/häfte 5
Sidor 1341-1349
ISSN 2168-2194
Publiceringsår 2018
Publicerad vid Institutionen för neurovetenskap och fysiologi
Sidor 1341-1349
Språk en
Länkar dx.doi.org/10.1109/jbhi.2017.277792...
Ämnesord Accelerometry, levodopa response, machine learning, parkinson's disease, pattern recognition, signal processing, wearable sensors, approximate entropy, dyskinesia, technology, tremor, scale, Computer Science, Mathematical & Computational Biology, Medical, Informatics
Ämneskategorier Neurovetenskaper

Sammanfattning

The goal of this study was to develop an algorithm that automatically quantifies motor states (off, on, dyskinesia) in Parkinson's disease (PD), based on accelerometry during a hand pronation-supination test. Clinician's ratings using the Treatment Response Scale (TRS), ranging from -3 (veryOff) to 0 (On) to +3 (very dyskinetic), were used as target. For that purpose, 19 participants with advanced PD and 22 healthy persons were recruited in a single center open label clinical trial in Uppsala, Sweden. The trial consisted of single levodopa dose experiments for the people with PD (PwP), where participants were asked to perform standardized wrist rotation tests, using each hand, before and at prespecified time points after the dose. The participants used wrist sensors containing a three-dimensional accelerometer and gyroscope. Features to quantify the level, variation, and asymmetry of the sensor signals, three-level discrete wavelet transform features, and approximate entropy measures were extracted from the sensors data. At the time of the tests, the PwP were video recorded. Three movement disorder specialists rated the participants' state on the TRS. A Treatment Response Index from Sensors (TRIS) was constructed to quantify the motor states based on the wrist rotation tests. Different machine learning algorithms were evaluated to map the features derived from the sensor data to the ratings provided by the three specialists. Results from cross validation, both in tenfold and a leave-one-individual out setting, showed good predictive power of a support vector machine model and high correlation to the TRS. Values at the end tails of the TRS were under and over predicted due to the lack of observations at those values but the model managed to accurately capture the dose-effect profiles of the patients. In addition, the TRIS had good test-retest reliability on the baseline levels of the PD participants (Intraclass correlation coefficient of 0.83) and reasonable sensitivity to levodopa treatment (0.33 for the TRIS). For a series of test occasions, the proposed algorithms provided dose-effect time profiles for participants with PD, which could be useful during therapy individualization of people suffering from advanced PD.

Sidansvarig: Webbredaktion|Sidan uppdaterades: 2012-09-11
Dela:

På Göteborgs universitet använder vi kakor (cookies) för att webbplatsen ska fungera på ett bra sätt för dig. Genom att surfa vidare godkänner du att vi använder kakor.  Vad är kakor?