Repeated Same-Day Versus Single Tomography Measurements of Keratoconic Eyes for Analysis of Disease Progression.

Artikel i vetenskaplig tidskrift
Författare Wolf Wonneberger
Bertil Sterner
Ulrika MacLean
Margareta Claesson
Madeleine Zetterberg
Publicerad i Cornea
Volym 37
Nummer/häfte 4
Sidor 474-479
ISSN 1536-4798
Publiceringsår 2018
Publicerad vid Institutionen för neurovetenskap och fysiologi
Institutionen för neurovetenskap och fysiologi, sektionen för klinisk neurovetenskap
Sidor 474-479
Språk en
Länkar dx.doi.org/10.1097/ICO.000000000000...
www.ncbi.nlm.nih.gov/entrez/query.f...
Ämneskategorier Oftalmologi

Sammanfattning

Corneal tomography is used to assess progression of keratoconus and to direct clinical decisions regarding corneal cross-linking. The purpose of this study was to analyze the variability of repeated Scheimpflug-tomography (Pentacam Classic; Oculus, Wetzlar, Germany) measurements of keratoconic eyes in a clinical setting and to assess the validity of such measurements as a clinical decision-making tool.Eighty keratoconic eyes of 45 patients (age range 16-32 years) were examined at baseline and after follow-up periods of 3 to 6 months using 3 consecutive tomography measurements at each visit. Minimum corneal thickness and anterior sagittal curvature map parameters were studied [simulated keratometry (K) astigmatism (SimKast); maximum simulated K-reading (SimKmax); average SimK (SimKave); maximum K-readings on the 3-mm (Kmax3) and 5-mm (Kmax5) rings; and maximum K-reading (Kmax)].When comparing the first measurements at the first and second visits, respectively, 9% to 20% of eyes were classified as progressive depending on which parameter was chosen. Using the average of 3 consecutive measurements at each visit, 5% to 19% of eyes were classified as progressive. An increase in the SD of 3 consecutive measurements of SimKast (SD_SimKast) at the first visit of 1 diopter makes true progression of keratoconus 3.6 times more likely (odds ratio = 3.6; 95% confidence interval: 0.846-16.027; area under the curve = 0.70).The approach used to analyze progression in keratoconus, that is, single versus repeated measurements, may confer a great impact on the decision to perform corneal cross-linking treatment or not.