Till sidans topp

Sidansvarig: Webbredaktion
Sidan uppdaterades: 2012-09-11 15:12

Tipsa en vän
Utskriftsversion

A collinear angle-resolve… - Göteborgs universitet Till startsida
Webbkarta
Till innehåll Läs mer om hur kakor används på gu.se

A collinear angle-resolved photoelectron spectrometer

Artikel i vetenskaplig tidskrift
Författare Olle Windelius
A. Aguilar
R. C. Bilodeau
A. M. Juarez
I. Rebolledo-Salgado
D. J. Pegg
Johan Rohlén
Jakob Welander
Dag Hanstorp
Publicerad i Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
Volym 410
Sidor 144-152
ISSN 0168-583X
Publiceringsår 2017
Publicerad vid Institutionen för fysik (GU)
Sidor 144-152
Språk en
Länkar doi.org/10.1016/j.nimb.2017.08.028
Ämnesord Angular distributions, Photodetachment, Photoelectron spectroscopy, Photoionization, Synchrotron radiation, Angular distribution, Electron multipliers, Electrons, Ion beams, Ionization, Photoelectrons, Spectrometers, Spectroscopic analysis, Synchrotrons, Angle-resolved photoelectron, Angular distribution measurements, Channel electron multipliers, Effective interactions, Electrostatic energy analyzers, Photo-detachment, Photoelectron signals, Photoelectron spectrometers, Photons
Ämneskategorier Fysik

Sammanfattning

In the present paper we describe a newly designed collinear photoelectron spectrometer for angular distribution measurements. We will henceforth refer to this instrument by the acronym PEARLS (PhotoElectron Angle-Resolved Linear Spectrometer). The design was motivated by the desire to collect electrons emitted from an extended linear source consisting of collinear photon and ion beams at a synchrotron radiation site. The electrons could be produced in either photoionization or photodetachment events. The primary advantage of a collinear beams geometry is that the effective interaction volume can be made much larger than that obtainable with a crossed beams geometry, which has been used in many earlier photoelectron spectroscopic studies. The present apparatus is capable of collecting electrons over a beam source length of 22 cm. The electrons are detected using Channel Electron Multipliers (CEMs). There are 4 detector planes placed perpendicular to the direction of the beam source, where each plane contains 4 CEMs. The use of all 4 detector planes with a total of 16 CEMs enhances the photoelectron signal, which is important at a synchrotron radiation site where the photon flux is typically low. If photoelectrons of different energies are emitted, the design allows for electrostatic energy analyzers to be placed in front of the CEMs. We have performed a photodetachment experiment to demonstrate the functionality of the PEARLS apparatus using a pulsed laser as the photon source. In particular, we have measured the angular distribution of photoelectrons ejected from Ag- at two different photon energies. © 2017 Elsevier B.V.

Sidansvarig: Webbredaktion|Sidan uppdaterades: 2012-09-11
Dela:

På Göteborgs universitet använder vi kakor (cookies) för att webbplatsen ska fungera på ett bra sätt för dig. Genom att surfa vidare godkänner du att vi använder kakor.  Vad är kakor?