Multi-atlas attenuation correction supports full quantification of static and dynamic brain PET data in PET-MR.

Artikel i vetenskaplig tidskrift
Författare Inés Mérida
Anthonin Reilhac
Jérôme Redouté
Rolf A. Heckemann
Nicolas Costes
Alexander Hammers
Publicerad i Physics in medicine and biology
Volym 62
Nummer/häfte 7
Sidor 2834-2858
ISSN 1361-6560
Publiceringsår 2017
Publicerad vid
Sidor 2834-2858
Språk en
Länkar dx.doi.org/10.1088/1361-6560/aa5f6c
www.ncbi.nlm.nih.gov/entrez/query.f...
Ämneskategorier Neurovetenskap, Radiologi och bildbehandling

Sammanfattning

In simultaneous PET-MR, attenuation maps are not directly available. Essential for absolute radioactivity quantification, they need to be derived from MR or PET data to correct for gamma photon attenuation by the imaged object. We evaluate a multi-atlas attenuation correction method for brain imaging (MaxProb) on static [(18)F]FDG PET and, for the first time, on dynamic PET, using the serotoninergic tracer [(18)F]MPPF. A database of 40 MR/CT image pairs (atlases) was used. The MaxProb method synthesises subject-specific pseudo-CTs by registering each atlas to the target subject space. Atlas CT intensities are then fused via label propagation and majority voting. Here, we compared these pseudo-CTs with the real CTs in a leave-one-out design, contrasting the MaxProb approach with a simplified single-atlas method (SingleAtlas). We evaluated the impact of pseudo-CT accuracy on reconstructed PET images, compared to PET data reconstructed with real CT, at the regional and voxel levels for the following: radioactivity images; time-activity curves; and kinetic parameters (non-displaceable binding potential, BPND). On static [(18)F]FDG, the mean bias for MaxProb ranged between 0 and 1% for 73 out of 84 regions assessed, and exceptionally peaked at 2.5% for only one region. Statistical parametric map analysis of MaxProb-corrected PET data showed significant differences in less than 0.02% of the brain volume, whereas SingleAtlas-corrected data showed significant differences in 20% of the brain volume. On dynamic [(18)F]MPPF, most regional errors on BPND ranged from -1 to  +3% (maximum bias 5%) for the MaxProb method. With SingleAtlas, errors were larger and had higher variability in most regions. PET quantification bias increased over the duration of the dynamic scan for SingleAtlas, but not for MaxProb. We show that this effect is due to the interaction of the spatial tracer-distribution heterogeneity variation over time with the degree of accuracy of the attenuation maps. This work demonstrates that inaccuracies in attenuation maps can induce bias in dynamic brain PET studies. Multi-atlas attenuation correction with MaxProb enables quantification on hybrid PET-MR scanners, eschewing the need for CT.