High proximal migration in cemented acetabular revisions operated with bone impaction grafting; 47 revision cups followed with RSA for 17 years.

Artikel i vetenskaplig tidskrift
Författare Maziar Mohaddes
Peter Herberts
Henrik Malchau
Per-Erik Johanson
Johan Kärrholm
Publicerad i Hip international : the journal of clinical and experimental research on hip pathology and therapy
Volym 27
Nummer/häfte 3
Sidor 251-258
ISSN 1724-6067
Publiceringsår 2017
Publicerad vid Institutionen för kliniska vetenskaper, Avdelningen för ortopedi
Sidor 251-258
Språk en
Länkar dx.doi.org/10.5301/hipint.5000452
www.ncbi.nlm.nih.gov/entrez/query.f...
Ämneskategorier Ortopedi

Sammanfattning

Bone impaction grafting is a biologically and mechanically appealing option in acetabular revision surgery, allowing restitution of the bone stock and restoration of the biomechanics. We analysed differences in proximal migration of the revision acetabular components when bone impaction grafting is used together with a cemented or an uncemented cup.43 patients (47 hips), revised due to acetabular loosening and judged to have less than 50% host bone-implant contact were included. The hips were randomised to either an uncemented (n = 20) or a cemented (n = 27) revision cup. Radiostereometry and radiography was performed postoperatively, at 3 and 6 months, 1, 2, 3, 5, 7, 10 and 13 and 17 years postoperatively. Clinical follow-up was performed at 1, 2 and 5 years postoperatively and thereafter at the same interval as in the radiographic follow-up.There were no differences in the base line demographic data between the 2 groups. At the last follow-up (17 years) 14 hips (10 cemented, 4 uncemented) had been re-revised due to loosening. 3 additional cups (1 uncemented and 2 cemented) were radiographically loose. There was a higher early proximal migration in the cemented cups.Cups operated on with cement showed a higher early migration measured with RSA and also a higher number of late revisions. The reason for this is not known, but factors such as inclusion of cases with severe bone defects, use of smaller bone chips and issues related to the impaction technique might have had various degrees of influence.