Till sidans topp

Sidansvarig: Webbredaktion
Sidan uppdaterades: 2012-09-11 15:12

Tipsa en vän
Utskriftsversion

Fatigue analysis of compu… - Göteborgs universitet Till startsida
Webbkarta
Till innehåll Läs mer om hur kakor används på gu.se

Fatigue analysis of computer-aided design/computer-aided manufacturing resin-based composite vs. lithium disilicate glass-ceramic

Artikel i vetenskaplig tidskrift
Författare S. Ankyu
K. Nakamura
A. Harada
G. Hong
T. Kanno
Y. Niwano
Ulf Örtengren
H. Egusa
Publicerad i European Journal of Oral Sciences
Volym 124
Nummer/häfte 4
Sidor 387-395
ISSN 0909-8836
Publiceringsår 2016
Publicerad vid Institutionen för odontologi, sektion 3
Sidor 387-395
Språk en
Länkar dx.doi.org/10.1111/eos.12278
Ämnesord fatigue, lithium disilicate glass-ceramic, mechanical cycling, resin-based composite, thermal cycling, fracture-resistance, molar crowns, flexural strength, marginal, adaptation, dental restorations, surface, simulation, cements, stress, force, Dentistry
Ämneskategorier Odontologi

Sammanfattning

Resin-based composite molar crowns made by computer-aided design/computer-aided manufacturing (CAD/CAM) systems have been proposed as an inexpensive alternative to metal-ceramic or all-ceramic crowns. However, there is a lack of scientific information regarding fatigue resistance. This study aimed to analyze the fatigue behavior of CAD/CAM resin-based composite compared with lithium disilicate glass-ceramic. One-hundred and sixty bar-shaped specimens were fabricated using resin-based composite blocks [Lava Ultimate (LU); 3M/ESPE] and lithium disilicate glass-ceramic [IPS e.max press (EMP); Ivoclar/Vivadent]. The specimens were divided into four groups: no treatment (NT); thermal cycling (TC); mechanical cycling (MC); and thermal cycling followed by mechanical cycling (TCMC). Thermal cycling was performed by alternate immersion in water baths of 5 degrees C and 55 degrees C for 5 x 10(4) cycles. Mechanical cycling was performed in a three-point bending test, with a maximum load of 40 N, for 1.2 x 10(6) cycles. In addition, LU and EMP molar crowns were fabricated and subjected to fatigue treatments followed by load-to-failure testing. The flexural strength of LU was not severely reduced by the fatigue treatments. The fatigue treatments did not significantly affect the fracture resistance of LU molar crowns. The results demonstrate the potential of clinical application of CAD/CAM-generated resin-based composite molar crowns in terms of fatigue resistance.

Sidansvarig: Webbredaktion|Sidan uppdaterades: 2012-09-11
Dela:

På Göteborgs universitet använder vi kakor (cookies) för att webbplatsen ska fungera på ett bra sätt för dig. Genom att surfa vidare godkänner du att vi använder kakor.  Vad är kakor?