Comparison of the accuracy in kidney activity concentration estimates by the conjugate view and posterior view methods

Konferensbidrag (offentliggjort, men ej förlagsutgivet)
Författare Tobias Magnander
Johanna Svensson
Magnus Båth
Peter Gjertsson
Eva Forssell-Aronsson
Peter Bernhardt
Publicerad i Optimisation in X-ray and Molecular Imaging 2015 - the Fourth Malmö Conference on Medical Imaging, Gothenburg, Sweden, 28-30 May 2015
Publiceringsår 2015
Publicerad vid Institutionen för kliniska vetenskaper, Avdelningen för radiofysik
Institutionen för kliniska vetenskaper, Avdelningen för onkologi
Institutionen för medicin, avdelningen för molekylär och klinisk medicin
Språk en
Länkar www.delegia.com/app/Data/ProjectIma...
https://gup.ub.gu.se/file/187460
Ämneskategorier Radiofysik

Sammanfattning

Purpose: In nuclear medicine the conjugate view method (CV) is the most common method for activity quantifications in planar images. The advantage with the CV method is its depth independence, i.e. the activity concentrations can be calculated from two opposite planar images without the knowledge of depth. However, one disadvantage of the method that the signal to background ratio is dependent on the location of the object. This effect might increase the inaccuracy in the activity concentration estimates. Therefore, the activity in off-center objects might be better estimated by the camera projection with the shortest camera to object distance. The aim of the present study was to compare the CV method with a posterior-anterior (PA) projection method for estimation of 177Lu activity concentrations in the kidneys. Methods: The two methods were used to retrospectively determine and compare the left and right kidney activity concentration in 20 patients treated with 177Lu-DOTA-octreotate at Sahlgrenska University Hospital. The kidney was segmented in the SPECT or CT image using an appropriate segmentation algorithm. An attenuation map for 177Lu was created from the CT. Attenuated planar AP and PA projections were created from the SPECT and the attenuation map. The kidney VOI was projected onto the AP and PA projections. The activity concentration in the kidney was calculated using both the PA projection method (ACPA) and the CV method (ACCV) and the results were compared to the concentration in the kidney VOI in the SPECT. Results: The mean ratio between ACCV and the SPECT determined activity concentration was 1.99 with a standard deviation (SD) equal to 1.03 and the mean ratio between ACPA and the SPECT determined concentration was 1.66 with SD=0.80. Both methods demonstrated that the main problems with activity estimates from planar images are the influences of attenuation and the activity concentration in the under and overlying tissues. Conclusions: The present study shows that a true background estimate cannot be accurately performed with neither the CV nor the PA method and that the difficulties in obtaining a true background affect the CV method more than the PA method. The study indicates that the PA method gives a more accurate estimate of the kidney activity concentration than the CV method.