Till sidans topp

Sidansvarig: Webbredaktion
Sidan uppdaterades: 2012-09-11 15:12

Tipsa en vän
Utskriftsversion

Simultaneous or Delayed P… - Göteborgs universitet Till startsida
Webbkarta
Till innehåll Läs mer om hur kakor används på gu.se

Simultaneous or Delayed Placement of Surface Modified and Fluoridated Dental Implants into Autogenous Block Bone Grafts: A Histologic and Biomechanical Study in the Rabbit.

Artikel i vetenskaplig tidskrift
Författare Amir Dasmah
Carl Rasmusson
Andreas Thor
Lars Rasmusson
Publicerad i Clinical implant dentistry and related research
Volym 17
Nummer/häfte 2
Sidor 395-401
ISSN 1708-8208
Publiceringsår 2015
Publicerad vid Institutionen för odontologi
Sidor 395-401
Språk en
Länkar dx.doi.org/10.1111/cid.12095
Ämneskategorier Odontologi

Sammanfattning

BACKGROUND: A delayed approach is recommended for reconstruction of the jaws with autogenous bone grafts and dental implants. Experimental studies have shown stronger bone tissue responses to surface modified implants than to nonmodified ones. AIM: The aim of the study was to evaluate bone integration and stability of surface modified and fluoridated implants when placed with fresh or healed autogenous bone grafts. MATERIAL AND METHODS: Six rabbits were used in this study. Each right rabbit tibia (control) received an autogenous bone graft, harvested from the calvarium. Eight weeks later, a second graft was harvested from the other side of the calvarium and placed on the left tibia (test) with an implant. Another implant was installed in the healed graft of the right tibia. TiO2 -blasted and fluoridated OsseoSpeed(TM) implants (Astra Tech AB, Mölndal, Sweden), 3.5 mm in diameter and 9 mm long, were used. After additional 8 weeks, the rabbits were sacrificed and the implants were removed en bloc for light-microscopic analysis. Bone-to-implant contact (BIC) was registered as well as the amount of bone filling a rectangle indicating a region of interest (ROI). Resonance frequency analysis (RFA) was conducted both at the time of surgery and at the end of the experiment. RESULTS: There were no statistically significant differences either in BIC or ROI between the test and control sides. RFA showed higher implant stability for the control side at the time of the surgery, but the difference had leveled out at the time of the sacrifice. CONCLUSION: The present study showed similar bone tissue responses and stability for surface modified and fluoridated implants after 8 weeks of healing in fresh or healed autogenous bone grafts.

Sidansvarig: Webbredaktion|Sidan uppdaterades: 2012-09-11
Dela:

På Göteborgs universitet använder vi kakor (cookies) för att webbplatsen ska fungera på ett bra sätt för dig. Genom att surfa vidare godkänner du att vi använder kakor.  Vad är kakor?