Till sidans topp

Sidansvarig: Webbredaktion
Sidan uppdaterades: 2012-09-11 15:12

Tipsa en vän
Utskriftsversion

One-Year Results of a Cli… - Göteborgs universitet Till startsida
Webbkarta
Till innehåll Läs mer om hur kakor används på gu.se

One-Year Results of a Clinical and Radiological Prospective Multicenter Study on NEOSS® Dental Implants.

Artikel i vetenskaplig tidskrift
Författare Christer Dahlin
Göran Widmark
Göran Bergkvist
Björn Fürst
Tor Widbom
Hossein Kashani
Publicerad i Clinical implant dentistry and related research
ISSN 1708-8208
Publiceringsår 2013
Publicerad vid Institutionen för odontologi
Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap
Språk en
Länkar dx.doi.org/10.1111/j.1708-8208.2011...
Ämneskategorier Biomaterial

Sammanfattning

Background: NEOSS® (Neoss Ltd., Harrogate, UK) dental implant system was introduced on the clinical arena in 2003. It is important that novel implant systems are systematically evaluated in a multicenter setting. Purpose: The aim of this study was to follow a large number of consecutively treated patients, with NEOSS dental implant system, both clinically and radiographically. The current report constitutes the 1-year data of a planned 5-year study. Materials and Methods: The study included a total of 177 patients treated with 590 NEOSS implants at 13 clinics in Sweden. The material was composed of 72 males and 105 females treated for single, partial, and total edentulism. Clinical, radiographic, and subjective evaluations were performed. Results: Out of 590 implants, 13 early failures have been reported, corresponding to a 1-year cumulative survival rate (CSR) of 97.8%. Evaluation of function and esthetics at the 1-year visit resulted in 100% success for function and 98% success for the esthetic outcome. The mean marginal bone loss was 0.6 mm (SD 1.1) after 1 year in clinical function. No adverse effects of the NEOSS dental implants were reported, and complications were few and similar to those reported for implant treatment in general. Conclusion: The CSR in the present study was 97.8%. No adverse effects of the NEOSS implants were reported, and complications during the study period were few and similar to those reported to for other well-documented implants system. Based on the present data, we conclude that NEOSS dental implant is a safe and predictable implant system. However, the high number of dropouts in the radiological evaluation must be considered when interpreting the data.

Sidansvarig: Webbredaktion|Sidan uppdaterades: 2012-09-11
Dela:

På Göteborgs universitet använder vi kakor (cookies) för att webbplatsen ska fungera på ett bra sätt för dig. Genom att surfa vidare godkänner du att vi använder kakor.  Vad är kakor?