Till sidans topp

Sidansvarig: Webbredaktion
Sidan uppdaterades: 2012-09-11 15:12

Tipsa en vän
Utskriftsversion

Grip control and motor co… - Göteborgs universitet Till startsida
Webbkarta
Till innehåll Läs mer om hur kakor används på gu.se

Grip control and motor coordination with implanted and surface electrodes while grasping with an osseointegrated prosthetic hand

Artikel i vetenskaplig tidskrift
Författare E. Mastinu
F. Clemente
P. Sassu
O. Aszmann
Rickard Brånemark
B. Håkansson
M. Controzzi
C. Cipriani
M. Ortiz-Catalan
Publicerad i Journal of Neuroengineering and Rehabilitation
Volym 16
Nummer/häfte 1
ISSN 1743-0003
Publiceringsår 2019
Publicerad vid Institutionen för kliniska vetenskaper, Avdelningen för ortopedi
Språk en
Länkar dx.doi.org/10.1186/s12984-019-0511-...
Ämnesord Electromyography (EMG), Epimysial, Implanted electrodes, Osseointegration, Prosthetic control, Article, auditory feedback, controlled study, electromyography, experimental locomotor activity test, grip force, hand grip, human, limb amputation, motor coordination, osseointegrated prosthetic hand, osseoperceptive feedback, pick and lift test, priority journal, sensory feedback, transhumeral amputation, virtual eggs test, visual feedback
Ämneskategorier Ortopedi

Sammanfattning

Background: Replacement of a lost limb by an artificial substitute is not yet ideal. Resolution and coordination of motor control approximating that of a biological limb could dramatically improve the functionality of prosthetic devices, and thus reduce the gap towards a suitable limb replacement. Methods: In this study, we investigated the control resolution and coordination exhibited by subjects with transhumeral amputation who were implanted with epimysial electrodes and an osseointegrated interface that provides bidirectional communication in addition to skeletal attachment (e-OPRA Implant System). We assessed control resolution and coordination in the context of routine and delicate grasping using the Pick and Lift and the Virtual Eggs Tests. Performance when utilizing implanted electrodes was compared with the standard-of-care technology for myoelectric prostheses, namely surface electrodes. Results: Results showed that implanted electrodes provide superior controllability over the prosthetic terminal device compared to conventional surface electrodes. Significant improvements were found in the control of the grip force and its reliability during object transfer. However, these improvements failed to increase motor coordination, and surprisingly decreased the temporal correlation between grip and load forces observed with surface electrodes. We found that despite being more functional and reliable, prosthetic control via implanted electrodes still depended highly on visual feedback. Conclusions: Our findings indicate that incidental sensory feedback (visual, auditory, and osseoperceptive in this case) is insufficient for restoring natural grasp behavior in amputees, and support the idea that supplemental tactile sensory feedback is needed to learn and maintain the motor tasks internal model, which could ultimately restore natural grasp behavior in subjects using prosthetic hands. © 2019 The Author(s).

Sidansvarig: Webbredaktion|Sidan uppdaterades: 2012-09-11
Dela:

På Göteborgs universitet använder vi kakor (cookies) för att webbplatsen ska fungera på ett bra sätt för dig. Genom att surfa vidare godkänner du att vi använder kakor.  Vad är kakor?