Effects of changing skin mechanics on the differential sensitivity to surface compliance by tactile afferents in the human finger pad

Artikel i vetenskaplig tidskrift
Författare K. M. Hudson
M. Condon
Rochelle Ackerley
F. McGlone
Håkan Olausson
V. G. Macefield
I. Birznieks
Publicerad i Journal of Neurophysiology
Volym 114
Nummer/häfte 4
Sidor 2249-2257
ISSN 0022-3077
Publiceringsår 2015
Publicerad vid Institutionen för neurovetenskap och fysiologi, sektionen för fysiologi
Sidor 2249-2257
Språk en
Länkar dx.doi.org/10.1152/jn.00176.2014
Ämnesord Human, Microneurography, Sensory coding, Skin mechanics, Tactile afferents
Ämneskategorier Neurovetenskaper, Klinisk neurofysiologi

Sammanfattning

It is not known how changes in skin mechanics affect the responses of cutaneous mechanoreceptors in the finger pads to compression forces. We used venous occlusion to change the stiffness of the fingers and investigated whether this influenced the firing of low-threshold mechanoreceptors to surfaces of differing stiffness. Unitary recordings were made from 10 slowly adapting type I (SAI), 10 fast adapting type I (FAI) and 9 slowly adapting type II (SAII) units via tungsten microelectrodes inserted into the median nerve at the wrist. A servocontrolled stimulator applied ramp-and-hold forces (1, 2, and 4 N) at a constant loading and unloading rate (2 N/s) via a flat 2.5-cmdiameter silicone disk over the center of the finger pad. Nine silicone disks (objects), varying in compliance, were used. Venous occlusion, produced by inflating a sphygmomanometer cuff around the upper arm to 40±5 mmHg, was used to induce swelling of the fingers and increase the compliance of the finger pulp. Venous occlusion had no effect on the firing rates of the SAI afferents, nor on the slopes of the relationship between mean firing rate and object compliance at each amplitude, but did significantly reduce the slopes for the FAI afferents. Although the SAII afferents possess a poor capacity to encode changes in object compliance, mean firing rates were significantly lower during venous occlusion. The finding that venous occlusion had no effect on the firing properties of SAI afferents indicates that these afferents preserve their capacity to encode changes in object compliance, despite changes in skin mechanics. © 2015 the American Physiological Society.