Different patterns of bone fixation with hydroxyapatite and resorbable CaP coatings in the rabbit tibia at 6, 12, and 52 weeks.

Artikel i vetenskaplig tidskrift
Författare Ole Reigstad
Carina B. Johansson
Victoria Franke Stenport
Ann Wennerberg
Astor Reigstad
Magne Røkkum
Publicerad i Journal of biomedical materials research. Part B, Applied biomaterials
Volym 99
Nummer/häfte 1
Sidor 14-20
ISSN 1552-4981
Publiceringsår 2011
Publicerad vid Institutionen för odontologi
Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap
Sidor 14-20
Språk en
Länkar dx.doi.org/10.1002/jbm.b.31866
Ämneskategorier Odontologi, Biomaterial

Sammanfattning

Applying bioactive coatings on orthopedic implants can increase the fixation and long-term implant survival. In our study, we compared a resorbable electrochemically deposited calcium phosphate coating (Bonit(®) ) to a thin (40 μm) plasma-sprayed hydroxyapatite (HA) coating, applied on grit-blasted screw-shaped Ti-6Al-4V implants in the cortical region of rabbit tibia, implanted for 6, 12, and 52 weeks. The removal torque results demonstrated stronger bone-to-implant fixation for the HA than Bonit-coated screws at 6 and 12 weeks. After 52 weeks, the fixation was in favor of the Bonit-coated screws, but the difference was statistically insignificant. Coat flaking and delamination of the HA with multinucleated giant cell activity and bone resorption observed histologically seemed to preclude any significant increase in fixation comparing the HA implants at 6 versus 12 weeks and 12 versus 52 weeks. The Bonit-coated implants exhibited increasing fixation from 6 to 12 weeks and from 12 to 52 weeks, and the coat was resorbed within 6 weeks, with minimal activity of multinucleated giant cells or bone resorption. A different fixation pattern was observed for the two coatings with a sharper but time limited increase in fixation for the HA-coated screws, and a slower but more steadily increasing fixation pattern for the Bonit-coated screws. The side effects were more serious for the HA coating and limiting the expected increase in fixation with time. © 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2011.