On osseointegration in relation to implant surfaces

Artikel i vetenskaplig tidskrift
Författare Tomas Albrektsson
Ann Wennerberg
Publicerad i Clinical Implant Dentistry and Related Research
Volym 21
Sidor 4-7
ISSN 1523-0899
Publiceringsår 2019
Publicerad vid Institutionen för odontologi
Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap
Sidor 4-7
Språk en
Länkar dx.doi.org/10.1111/cid.12742
Ämnesord implant surface, osseointegration, titanium, foreign-body reaction, titanium implants, osteogenic markers, gene-expression, bone loss, proliferation, magnesium, adhesion, tissue, discs
Ämneskategorier Biomaterial

Sammanfattning

Background The understanding of mechanisms of osseointegration as well as applied knowledge about oral implant surfaces are of paramount importance for successful clinical results. Purpose The aim of the present article is to present an overview of osseointegration mechanisms and an introduction to surface innovations with relevance for osseointegration that will be published in the same supplement of Clinical Implant Dentistry and Related Research. Materials and Methods The present article is a narrative review of some osseointegration and implant surface-related details. Results and Conclusions Osseointegration has a changed definition since it is realized today that oral implants are but foreign bodies and that this fact explains osseointegration as a protection mechanism of the tissues. Given adequate stability, bone tissue is formed around titanium implants to shield them from the tissues. Oral implant surfaces may be characterized by microroughness and nanoroughness, by surface chemical composition and by physical and mechanical parameters. An isotropic, moderately rough implant surface such as seen on the TiUnite device has displayed improved clinical results compared to previously used minimally rough or rough surfaces. However, there is a lack of clinical evidence supporting any particular type of nanoroughness pattern that, at best, is documented with results from animal studies. It is possible, but as yet unproven, that clinical results may be supported by a certain chemical composition of the implant surface. The same can be said with respect to hydrophilicity of implant surfaces; positive animal data may suggest some promise, but there is a lack of clinical evidence that hydrophilic implants result in improved clinical outcome of more hydrophobic surfaces. With respect to mechanical properties, it seems obvious that those must be encompassing the loading of oral implants, but we need more research on the mechanically ideal implant surface from a clinical aspect.