Measurement of protein backbone (CO)-C-13 and N-15 relaxation dispersion at high resolution

Artikel i vetenskaplig tidskrift
Författare Maxim Mayzel
A. Ahlner
P. Lundstrom
Vladislav Orekhov
Publicerad i Journal of Biomolecular NMR
Volym 69
Nummer/häfte 1
Sidor 1-12
ISSN 0925-2738
Publiceringsår 2017
Publicerad vid Svenskt NMR-centrum vid Göteborgs universitet
Institutionen för kemi och molekylärbiologi
Sidor 1-12
Språk en
Länkar https://doi.org/10.1007/s10858-017-...
Ämnesord NMR, NUS, IDP, Conformational exchange, Dynamics, Target acquisition, invisible excited-states, nmr-spectroscopy, chemical-shifts, multidimensional nmr, dynamics, decomposition, sequence, pulses, Biochemistry & Molecular Biology, Spectroscopy
Ämneskategorier Biokemi och molekylärbiologi, Spektroskopi

Sammanfattning

Peak overlap in crowded regions of two-dimensional spectra prevents characterization of dynamics for many sites of interest in globular and intrinsically disordered proteins. We present new three-dimensional pulse sequences for measurement of Carr-Purcell-Meiboom-Gill relaxation dispersions at backbone nitrogen and carbonyl positions. To alleviate increase in the measurement time associated with the additional spectral dimension, we use non-uniform sampling in combination with two distinct methods of spectrum reconstruction: compressed sensing and co-processing with multi-dimensional decomposition. The new methodology was validated using disordered protein CD79A from B-cell receptor and an SH3 domain from Abp1p in exchange between its free form and bound to a peptide from the protein Ark1p. We show that, while providing much better resolution, the 3D NUS experiments give the similar accuracy and precision of the dynamic parameters to ones obtained using traditional 2D experiments. Furthermore, we show that jackknife resampling of the spectra yields robust estimates of peak intensities errors, eliminating the need for recording duplicate data points.