Till sidans topp

Sidansvarig: Webbredaktion
Sidan uppdaterades: 2012-09-11 15:12

Tipsa en vän
Utskriftsversion

Exhaled Endogenous Partic… - Göteborgs universitet Till startsida
Webbkarta
Till innehåll Läs mer om hur kakor används på gu.se

Kontaktformulär








 


OBS! Vill du ha svar, ange e-post eller telefonnummer!




Exhaled Endogenous Particles Contain Lung Proteins.

Artikel i vetenskaplig tidskrift
Författare Anna Bredberg
Johan Gobom
Ann-Charlotte Almstrand
Per Larsson
Kaj Blennow
Anna-Carin Olin
Ekaterina Mirgorodskaya
Publicerad i Clinical Chemistry
Volym 58
Nummer/häfte 2
Sidor 431-440
ISSN 1530-8561
Publiceringsår 2012
Publicerad vid Institutionen för medicin, avdelningen för samhällsmedicin och folkhälsa
Institutionen för neurovetenskap och fysiologi, sektionen för psykiatri och neurokemi
Sidor 431-440
Språk en
Länkar dx.doi.org/10.1373/clinchem.2011.16...
Ämneskategorier Dermatologi och venereologi

Sammanfattning

BACKGROUND:We recently developed a novel, noninvasive method for sampling nonvolatile material from the distal airways. The method is based on the collection of endogenous particles in exhaled air (PEx). The aim of this study was to characterize the protein composition of PEx and to verify that the origin of PEx is respiratory tract lining fluid (RTLF).METHOD:Healthy individuals exhaled into the sampling device, which collected PEx onto a silicon plate inside a 3-stage impactor. After their extraction from the plates, PEx proteins were separated by SDS-PAGE and then analyzed by LC-MS. Proteins were identified by searching the International Protein Index human database with the Mascot search engine.RESULTS:Analysis of the pooled samples identified 124 proteins. A comparison of the identified PEx proteins with published bronchoalveolar lavage (BAL) proteomic data showed a high degree of overlap, with 103 (83%) of the PEx proteins having previously been detected in BAL. The relative abundances of the proteins were estimated according to the Mascot exponentially modified protein abundance index protocol and were in agreement with the expected protein composition of RTLF. No amylase was detected, indicating the absence of saliva protein contamination with our sampling technique.CONCLUSIONS:Our data strongly support that PEx originate from RTLF and reflect the composition of undiluted RTLF.

Sidansvarig: Webbredaktion|Sidan uppdaterades: 2012-09-11
Dela:

På Göteborgs universitet använder vi kakor (cookies) för att webbplatsen ska fungera på ett bra sätt för dig. Genom att surfa vidare godkänner du att vi använder kakor.  Vad är kakor?