To the top

Page Manager: Webmaster
Last update: 9/11/2012 3:13 PM

Tell a friend about this page
Print version

Tissue characteristics at… - University of Gothenburg, Sweden Till startsida
Sitemap
To content Read more about how we use cookies on gu.se

Tissue characteristics at microthreaded implants: an experimental study in dogs.

Journal article
Authors Ingemar Abrahamsson
Tord Berglundh
Published in Clinical implant dentistry and related research
Volume 8
Issue 3
Pages 107-13
ISSN 1523-0899
Publication year 2006
Published at Institute of Odontology
Pages 107-13
Language en
Links dx.doi.org/10.1111/j.1708-8208.2006...
Keywords Alveolar Bone Loss, pathology, radiography, Animals, Bicuspid, Biopsy, Bone Density, physiology, Crowns, Dental Abutments, Dental Implants, Dental Prosthesis Design, Dental Prosthesis, Implant-Supported, Denture, Partial, Fixed, Dogs, Mandible, pathology, physiopathology, radiography, Osseointegration, physiology, Surface Properties, Time Factors
Subject categories Dentistry, Biomaterials

Abstract

PURPOSE: The aim of the present study was to analyze bone tissue reactions at implants with and without a microthread configuration. MATERIALS AND METHODS: In six beagle dogs, one test and two control implants were installed in one side of the mandible. While both implant types had a similar dimension and surface roughness, the test implants were designed with a microthread configuration in the marginal portion. Abutment connection was performed after 3 months. Another 3 months later, fixed partial dentures (FPDs) were cemented to the maxillary canine and premolars and FPDs were connected to the implants in the mandible. Ten months later, the animals were sacrificed and biopsies from each implant region were processed for histological analysis. Radiographs were obtained at implant placement after FPD connection and at the termination of the experiment. RESULTS: The radiographic examination revealed that the marginal bone level was well preserved at both test and control implants during the entire 16-month period. The degree of bone-implant contact within the marginal portion of the implants was significantly higher at the test (microthread) implants (81.8%) than at the control implants (72.8%). CONCLUSIONS: It was suggested that the microthread configuration offered improved conditions for osseointegration.

Page Manager: Webmaster|Last update: 9/11/2012
Share:

The University of Gothenburg uses cookies to provide you with the best possible user experience. By continuing on this website, you approve of our use of cookies.  What are cookies?