To the top

Page Manager: Webmaster
Last update: 9/11/2012 3:13 PM

Tell a friend about this page
Print version

A model for evaluation of… - University of Gothenburg, Sweden Till startsida
Sitemap
To content Read more about how we use cookies on gu.se

A model for evaluation of the electric activity and oxygenation in the erector spinae muscle during isometric loading adapted for spine patients

Journal article
Authors Lars Ekström
Qiuxia Zhang
Josefin Abrahamson
Joel Beck
Christer Johansson
Olof Westin
C. Todd
Adad Baranto
Published in Journal of Orthopaedic Surgery and Research
Volume 15
Issue 1
Pages 11
ISSN 1749-799X
Publication year 2020
Published at Institute of Clinical Sciences, Department of Orthopaedics
Pages 11
Language en
Links dx.doi.org/10.1186/s13018-020-01652...
Keywords Spinal stenosis, EMG, NIRS, Paraspinal muscle, Muscle oxygenation, Muscle activity, Laminectomy, low-back-pain, lumbar paraspinal muscles, surface-emg, electromyography, endurance, exercise, Orthopedics
Subject categories Orthopedics

Abstract

Background Simultaneous measurement of electromyography (EMG) and local muscle oxygenation is proposed in an isometric loading model adjusted for patients that have undergone spinal surgery. Methods Twelve patients with degenerative lumbar spinal stenosis (DLSS) were included. They were subjected to a test protocol before and after surgery. The protocol consisted of two parts, a dynamic and an isometric Ito loading with a time frame of 60 s and accompanying rest of 120 s. The Ito test was repeated three times. EMG was measured bilaterally at the L4 level and L2 and was recorded using surface electrodes and collected (Biopac Systems Inc.). EMG signal was expressed as RMS and median frequency (MF). Muscle tissue oxygen saturation (MrSO(2)) was monitored using a near-infrared spectroscopy (NIRS) device (INVOS (R) 5100C Oxymeter). Two NIRS sensors were positioned bilaterally at the L4 level. The intensity of the leg and back pain and perceived exertion before, during, and after the test was evaluated with a visual analogue scale (VAS) and Borg RPE-scale, respectively. Results All patients were able to perform and complete the test protocol pre- and postoperatively. A consistency of lower median and range values was noted in the sensors of EMG1 (15.3 mu V, range 4.5-30.7 mu V) and EMG2 (13.6 mu V, range 4.0-46.5 mu V) that were positioned lateral to NIRS sensors at L4 compared with EMG3 (18.9 mu V, range 6.5-50.0 mu V) and EMG4 (20.4 mu V, range 7.5-49.0 mu V) at L2. Right and left side of the erector spinae exhibited a similar electrical activity behaviour over time during Ito test (60 s). Regional MrSO(2) decreased over time during loading and returned to the baseline level during recovery on both left and right side. Both low back and leg pain was significantly reduced postoperatively. Conclusion Simultaneous measurement of surface EMG and NIRS seems to be a promising tool for objective assessment of paraspinal muscle function in terms of muscular activity and local muscle oxygenation changes in response to isometric trunk extension in patients that have undergone laminectomy for spinal stenosis.

Page Manager: Webmaster|Last update: 9/11/2012
Share:

The University of Gothenburg uses cookies to provide you with the best possible user experience. By continuing on this website, you approve of our use of cookies.  What are cookies?