To the top

Page Manager: Webmaster
Last update: 9/11/2012 3:13 PM

Tell a friend about this page
Print version

Dental implant register: … - University of Gothenburg, Sweden Till startsida
Sitemap
To content Read more about how we use cookies on gu.se

Dental implant register: Summary and consensus statements of group 2. The 5th EAO Consensus Conference 2018

Journal article
Authors B. Klinge
M. Sanz
G. Alcoforado
S. P. Bienz
J. Cosyn
H. De Bruyn
Jan Derks
E. Figuero
K. Gurzawska
L. Heitz-Mayfield
R. E. Jung
T. Ornekul
A. Sagado
Published in Clinical Oral Implants Research
Volume 29
Issue Supplement: 18
Pages 157-159
ISSN 0905-7161
Publication year 2018
Published at Institute of Odontology
Pages 157-159
Language en
Links dx.doi.org/10.1111/clr.13269
Keywords oceedings paper(1), sahlgrenska acad(1), univ(1), clinical assessment, diagnosis, epidemiology, patient centered outcomes, quality register, statistics, Dentistry, Oral Surgery & Medicine, Engineering
Subject categories Dentistry

Abstract

Objectives: This publication reports the EAO Workshop group-2 and consensus plenary discussions and statements on a narrative review providing the background and possible facilities and importance of a dental implant register, to allow for a systematic follow-up of the clinical outcome of dental implant treatment in various clinical settings. It should be observed that the format of the review and the subsequent consensus report consciously departs from conventional consensus publications and reports. Material and methods: The publication was a narrative review on the presence and significance of quality registers regarding select medical conditions and procedures. The group discussed and evaluated the publication and made corrections and recommendations to the authors and agreed on the statements and recommendations described in this consensus report. Results: Possible registrations to be included in an implant register were discussed and agreed as a preliminary basis for further development, meaning that additional parameters be included or some be deleted. Conclusions: It was agreed to bring the idea of an implant quality register, including the presented results of discussions and proposals by the group- and plenary sessions, to the EAO Board for further discussion and decision.

Page Manager: Webmaster|Last update: 9/11/2012
Share:

The University of Gothenburg uses cookies to provide you with the best possible user experience. By continuing on this website, you approve of our use of cookies.  What are cookies?