To the top

Page Manager: Webmaster
Last update: 9/11/2012 3:13 PM

Tell a friend about this page
Print version

Measurement of the size d… - University of Gothenburg, Sweden Till startsida
Sitemap
To content Read more about how we use cookies on gu.se

Measurement of the size distribution, volume fraction and optical properties of soot in an 80 kW propane flame

Journal article
Authors D. Backstrom
A. Gunnarsson
Dan Gall
Xiangyu Pei
Robert Johansson
K. Andersson
Ravi K. Pathak
Jan B. C. Pettersson
Published in Combustion and Flame
Volume 186
Pages 325-334
ISSN 0010-2180
Publication year 2017
Published at Department of Chemistry and Molecular Biology
Pages 325-334
Language en
Links doi.org/10.1016/combustflame.2017.0...
Keywords Soot, Radiative heat transfer, SMPS, PASS-3, oxy-fuel flames, coal flames, radiation intensity, combustion systems, light-absorption, gas radiation, heat-transfer, band model, particle, carbon, Thermodynamics, Energy & Fuels, Engineering
Subject categories Atom and Molecular Physics and Optics

Abstract

This work presents measurements of the size distribution, volume fraction, absorption and scattering coefficients of soot in an 80 kW swirling propane-fired flame. Extractive measurements were performed in the flame using an oil-cooled particle extraction probe. The particle size distribution was measured with a Scanning Mobility Particle Sizer (SMPS) and the optical properties were measured using a Photo Acoustic Soot Spectrometer (PASS-3). A detailed radiation model was used to examine the influence of the soot volume fraction on the particle radiation intensity. The properties of the gas were calculated with a statistical narrow-band model and the particle properties were calculated using Rayleigh theory with four different complex indices of refraction for soot particles. The modelled radiation was compared with measured total radiative intensity, the latter which was measured with a narrow angle radiometer. The results show that the measured soot volume fraction yields particle radiation that corresponds well with the determined difference between gas and total radiation. This indicates that the presented methodology is capable of quantifying both the particle and gaseous radiation in a flame of technical size. (C) 2017 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

Page Manager: Webmaster|Last update: 9/11/2012
Share:

The University of Gothenburg uses cookies to provide you with the best possible user experience. By continuing on this website, you approve of our use of cookies.  What are cookies?