To the top

Page Manager: Webmaster
Last update: 9/11/2012 3:13 PM

Tell a friend about this page
Print version

Information content with … - University of Gothenburg, Sweden Till startsida
Sitemap
To content Read more about how we use cookies on gu.se

Information content with low- vs. high-Tc SQUID arrays in MEG recordings: The case for high-Tc SQUID-based MEG

Journal article
Authors Justin F. Schneiderman
Published in Journal of Neuroscience Methods
Volume 222
Pages 42-46
ISSN 0165-0270
Publication year 2014
Published at Institute of Neuroscience and Physiology
Pages 42-46
Language en
Links dx.doi.org/10.1016/j.jneumeth.2013....
Keywords Channel capacity, High-Tc SQUID, MEG, Neuroimaging, SQUID-sensor arrays, Total information, analyzer, article, cerebrospinal fluid, electroencephalogram, magnetic field, magnetoencephalography, noise, priority journal, process optimization, recording, sensor, signal noise ratio, superconducting quantum interference device, white noise
Subject categories Neurosciences

Abstract

Background: Magnetoencephalography (MEG) is a method of studying brain activity via recordings of the magnetic field generated by neural activity. Modern MEG systems employ an array of low critical-temperature superconducting quantum interference devices (low-Tc SQUIDs) that surround the head. The geometric distribution of these arrays is optimized by maximizing the information content available to the system in brain activity recordings according to Shannon's theory of noisy channel capacity. New method: Herein, we present a theoretical comparison of the performance of low- and high-Tc SQUID-based multichannel systems in recordings of brain activity. Results: We find a high-Tc SQUID magnetometer-based multichannel system is capable of extracting at least 40% more information than an equivalent low-Tc SQUID system. The results suggest more information can be extracted from high-Tc SQUID MEG recordings (despite higher sensor noise levels than their low-Tc counterparts) because of the closer proximity to neural sources in the brain. Comparison with existing methods: We have duplicated previous results in terms of total information of multichannel low-Tc SQUID arrays for MEG. High-Tc SQUID technology theoretically outperforms its conventional low-Tc counterpart in MEG recordings. Conclusions: A full-head high-Tc SQUID-based MEG system's potential for extraction of more information about neural activity can be used to, e.g., develop better diagnostic and monitoring techniques for brain disease and enhance our understanding of the working human brain. © 2013 Elsevier B.V.

Page Manager: Webmaster|Last update: 9/11/2012
Share:

The University of Gothenburg uses cookies to provide you with the best possible user experience. By continuing on this website, you approve of our use of cookies.  What are cookies?