ViewDEX: an efficient and easy-to-use software for observer performance studies

Journal article
Authors Markus Håkansson
Sune Svensson
Sara Zachrisson
Angelica Svalkvist
Magnus Båth
Lars Gunnar Månsson
Published in Radiation protection dosimetry
Volume 139
Issue 1-3
Pages 42-51
ISSN 1742-3406
Publication year 2010
Published at Institute of Clinical Sciences, Department of Radiation Physics
Institute of Clinical Sciences
Pages 42-51
Language en
Links dx.doi.org/10.1093/rpd/ncq057
Subject categories Radiological physics

Abstract

The development of investigation techniques, image processing, workstation monitors, analysing tools etc. within the field of radiology is vast, and the need for efficient tools in the evaluation and optimisation process of image and investigation quality is important. ViewDEX (Viewer for Digital Evaluation of X-ray images) is an image viewer and task manager suitable for research and optimisation tasks in medical imaging. ViewDEX is DICOM compatible and the features of the interface (tasks, image handling and functionality) are general and flexible. The configuration of a study and output (for example, answers given) can be edited in any text editor. ViewDEX is developed in Java and can run from any disc area connected to a computer. It is free to use for non-commercial purposes and can be downloaded from http://www.vgregion.se/sas/viewdex. In the present work, an evaluation of the efficiency of ViewDEX for receiver operating characteristic (ROC) studies, free-response ROC (FROC) studies and visual grading (VG) studies was conducted. For VG studies, the total scoring rate was dependent on the number of criteria per case. A scoring rate of approximately 150 cases h(-1) can be expected for a typical VG study using single images and five anatomical criteria. For ROC and FROC studies using clinical images, the scoring rate was approximately 100 cases h(-1) using single images and approximately 25 cases h(-1) using image stacks ( approximately 50 images case(-1)). In conclusion, ViewDEX is an efficient and easy-to-use software for observer performance studies.

Page Manager: Webmaster|Last update: 9/11/2012
Share:

The University of Gothenburg uses cookies to provide you with the best possible user experience. By continuing on this website, you approve of our use of cookies.  What are cookies?