To the top

Page Manager: Webmaster
Last update: 9/11/2012 3:13 PM

Tell a friend about this page
Print version

Surface characterization … - University of Gothenburg, Sweden Till startsida
Sitemap
To content Read more about how we use cookies on gu.se

Surface characterization of commercial oral implants on the nanometer level.

Journal article
Authors Lory Melin Svanborg
Martin Andersson
Ann Wennerberg
Published in Journal of biomedical materials research. Part B, Applied biomaterials
Volume 92B
Issue 2
Pages 462-469
ISSN 1552-4981
Publication year 2010
Published at Institute of Clinical Sciences, Department of Biomaterials
Pages 462-469
Language en
Links dx.doi.org/10.1002/jbm.b.31538
Subject categories Biomaterials

Abstract

Lately, there has been a growing interest in how the presence of nanometer structures on a bone integrated implant surface influences the healing process. Recent in vitro studies have revealed an increased osteoblast response to different nanophase surfaces. Some commercial implant brands claim their implants have nanometer structures. However, at present, there are no studies where the nano topography of today's commercially available oral implants has been investigated. The aim of this study was to characterize commercial oral implants on the nanometer level and to investigate whether or not the nanometer surface roughness was correlated to the more well-known micrometer roughness on the implants. Twelve different commercial screw-shaped oral implants with various surface modifications were examined using scanning electron microscopy and a white light interferometer. The interferometer is suitable for detection of nanoscale roughness in the vertical dimension; however, limitation exists on the horizontal due to the wavelength of the light. A 1 x 1 mum Gaussian filter was found to be useful for identifying nm roughness with respect to height deviation. The results demonstrated that an implant that was smooth on the micrometer level was not necessarily smooth on the nanometer level. Different structures in the nanometer scale was found on some of the implants, indicating that to fully understand the relationship between the properties of an implant surface and its osseointegration behavior, a characterization at the nanometer scale might be relevant. (c) 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2010.

Page Manager: Webmaster|Last update: 9/11/2012
Share:

The University of Gothenburg uses cookies to provide you with the best possible user experience. By continuing on this website, you approve of our use of cookies.  What are cookies?