To the top

Page Manager: Webmaster
Last update: 9/11/2012 3:13 PM

Tell a friend about this page
Print version

Interferometric measureme… - University of Gothenburg, Sweden Till startsida
Sitemap
To content Read more about how we use cookies on gu.se

Interferometric measurements of dynamic changes of tear film.

Journal article
Authors Dorota H Szczesna
Jarosław Jaroński
Henryk T Kasprzak
Ulf Stenevi
Published in Journal of biomedical optics
Volume 11
Issue 3
Pages 34028
ISSN 1083-3668
Publication year 2006
Published at Institute of Neuroscience and Physiology, Department of Clinical Neuroscience and Rehabilitation
Pages 34028
Language en
Links dx.doi.org/10.1117/1.2209881
Keywords Dry Eye Syndromes, diagnosis, physiopathology, Equipment Design, Equipment Failure Analysis, Humans, Interferometry, instrumentation, methods, Kinetics, Lacrimal Apparatus Diseases, diagnosis, physiopathology, Refractometry, instrumentation, methods, Reproducibility of Results, Sensitivity and Specificity, Tears, chemistry
Subject categories Ophthalmology

Abstract

Tear film stability plays an important role in the quality of vision. We present an interferometric method for assessing the stability of precorneal tear film in real time. A lateral shearing technique is applied as a noninvasive and sensitive method for investigating tear film stability and the smoothness of the tear film surface by quantitative evaluation of the interference fringe pattern. The evaporation of tears and the appearance of tear film break-up between blinks cause changes in the fringe geometry. For quantitative assessment of the fringe smoothness and consequently of the tear film structure, the fast Fourier transform (FFT) is applied. Four parameters are used to quantitatively estimate dynamic changes in the tear film stability of the cornea 20 s after the eye blink. Examples of examined interferograms recorded in patients with healthy eyes, patients suffering from dry-eye syndrome, and patients wearing contact lenses are given. Significant differences between the stability of the tear film in the healthy eye and that in the dry eye and the eye with a contact lens are observed. The favorable influence of artificial tears applied in patients with dry-eye syndrome or contact lenses is also discussed.