To the top

Page Manager: Webmaster
Last update: 9/11/2012 3:13 PM

Tell a friend about this page
Print version

The open-top chamber impa… - University of Gothenburg, Sweden Till startsida
Sitemap
To content Read more about how we use cookies on gu.se

The open-top chamber impact on vapour pressure deficit and its consequences for stomatal ozone uptake

Journal article
Authors Kristin Piikki
L. De Temmerman
P Högy
Håkan Pleijel
Published in Atmospheric Environment
Volume 42
Issue 26
Pages 6513-6522
ISSN 1352-2310
Publication year 2008
Published at Department of Plant and Environmental Sciences
Pages 6513-6522
Language en
Links dx.doi.org/10.1016/j.atmosenv.2008....
Keywords open-top chamber, ozone ozone index, ozone uptake, risk assessment, vapour pressure deficit
Subject categories Environmental chemistry, Meteorology and Atmospheric Sciences, Botany, Agronomy

Abstract

The vapour pressure deficit (VPD) in open-top chambers (OTCs) was analysed in relation to time of day and ambient meteorology. Effects of observed VPD differences (ΔVPD) between OTCs and the ambient air (AA) on stomatal conductance (gs) were simulated using 10 model functions from the literature. The dataset originated from 17 OTC crop experiments performed in Belgium, Germany and Sweden. ΔVPD is the resulting difference between the OTC effect on es(T), which is the temperature-dependent saturation pressure of water vapour and the OTC effect on ea, which is the prevailing partial pressure of water vapour in the air (ΔVPD = Δes(T) − Δea). Both Δes(T) and Δea were positive during daylight hours. ΔVPD was small in comparison and sensitive to changes in Δes(T) or Δea. ΔVPD was negative between 07:30 and 10:30 and positive thereafter with a maximum at 20:30 (local time). The positive afternoon ΔVPD was due to an early decrease in Δea, probably caused by ceased transpiration, while the positive Δes(T) persisted throughout the evening, most likely because of restrained cooling in the OTCs. Both the negative morning ΔVPD and the positive evening ΔVPD were more pronounced during clear, warm and dry weather. Circumstances when VPD had a stronger limiting effect on gs inside the OTCs compared to in the ambient air coincided with high ambient ozone concentrations ([O3]). Calculated wheat O3 uptake over an [O3] threshold of 40 nmol mol−1 was reduced by 8.7% in OTCs, assuming that VPD was the only factor limiting gs and that gs was the only resistance for O3 uptake. VPD is one factor of considerable importance for gs and the OTC impact on VPD may contribute to an underestimation of O3 effects expressed in relation to the external O3 exposure.

Page Manager: Webmaster|Last update: 9/11/2012
Share:

The University of Gothenburg uses cookies to provide you with the best possible user experience. By continuing on this website, you approve of our use of cookies.  What are cookies?