To the top

Page Manager: Webmaster
Last update: 9/11/2012 3:13 PM

Tell a friend about this page
Print version

An interferometric method… - University of Gothenburg, Sweden Till startsida
Sitemap
To content Read more about how we use cookies on gu.se

An interferometric method for the dynamic evaluation of the tear film.

Journal article
Authors DH Szczesna
HT Kasprzak
J Jaronski
A Rydz
Ulf Stenevi
Published in Acta Ophthalmologica Scandinavica
Volume 85
Pages 202-208
ISSN Acta ophthalmologica Scandinavica
Publication year 2007
Published at Institute of Neuroscience and Physiology
Institute of Neuroscience and Physiology, Department of Clinical Neuroscience and Rehabilitation
Pages 202-208
Language en
Links doi: 10.1111/j.1600-0420.2006.00802...
Keywords cornea – dry eye – interferometry – tear film – contact lens – break-up time
Subject categories Medical and Health Sciences

Abstract

ABSTRACT. Purpose: This study describes a non-invasive method for the in vivo assessment of precorneal tear film stability. Methods: A lateral shearing interferometer (LSI) is used for the measurement. The interference fringes obtained from the tear film layer are analysed using the fast Fourier transform (FFT) technique. The method is based on evaluating the degree of fringe disturbance by calculation of the second momentum of Fourier spectra on the interferogram pattern. Results: This method points to the occurrence of dynamic changes in the tear film surface over time. We propose four different parameters. One of them is presented here. The less smooth the tear film, the more disturbed the interference fringes and the higher the value of the calculation parameters. Clear differences were discerned between tear film quality in healthy eyes, dry eyes and eyes with various contact lenses. The benefits of artificial tears used by patients with dry eye or contact lenses were also noted. Examination of dry eyes before and after applying fluorescein revealed significant differences in tear film stability. Conclusions: Lateral shearing interferometry is a suitable method for assessing the stability of the tear film on the cornea and on contact lenses. Evident differences can be demonstrated in tear film quality between normal eyes and dry eyes or eyes with soft contact lenses.

Page Manager: Webmaster|Last update: 9/11/2012
Share:

The University of Gothenburg uses cookies to provide you with the best possible user experience. By continuing on this website, you approve of our use of cookies.  What are cookies?