Clinical Outcome of Dental Implants Placed with High Insertion Torques (Up to 176 Ncm).

Journal article
Authors Philippe G Khayat
Hélène M Arnal
Bahige I Tourbah
Lars Sennerby
Published in Clinical implant dentistry and related research
ISSN 1708-8208
Publication year 2013
Published at Institute of Odontology
Language en
Links dx.doi.org/10.1111/j.1708-8208.2011...
Subject categories Biomaterials

Abstract

Background: Primary stability can be improved by using a tapered implant in a slightly underprepared implant site. This may lead to high compression forces and elevated insertion torques. It has been postulated that disturbance of the local microcirculation may occur, leading to necrosis of the osteocytes and bone resorption. Purpose: Report on the clinical outcome of 42 implants placed with an insertion torque equal or greater than 70 Ncm and evaluate bone levels around these implants. Materials and Methods: This prospective study included 48 patients treated with 66 4.5 mm diameter Tapered Screw-Vent implants (Zimmer Dental®, Carlsbad, CA, USA). Maximum insertion torque (MIT) was recorded with an electronic torque measuring device (Tohnichi® STC200CN, Hitachi, Tokyo, Japan). Nine implants (control group) presented MIT between 30 and 50 Ncm (mean = 37.1 Ncm) and 42 implants (experimental group) MIT greater than 70 Ncm (mean = 110.6 Ncm, range: 70.8-176 Ncm). Marginal bone levels were recorded at the time of loading and 1 year later for the two groups. Results: After 2-3 months of non-sumerged healing, all implants were clinically stable. Mean marginal bone resorption was 1.03 mm (SD = 0.44) for the control group (low torque) and 0.72 mm (SD = 0.56) for the experimental group (high torque) at time of loading, and 1.09 (SD = 0.62) and 1.24 mm (SD = 0.75), respectively, after 1 year. There were no significant differences between the two groups for bone stability and implant success rate. Conclusions: The use of high insertion torques (up to 176 Ncm) did not prevent osseointegration. Marginal bone levels in the control and experimental groups were similar both at the time of loading and 1 year later.

Page Manager: Webmaster|Last update: 9/11/2012
Share:

The University of Gothenburg uses cookies to provide you with the best possible user experience. By continuing on this website, you approve of our use of cookies.  What are cookies?