To the top

Page Manager: Webmaster
Last update: 9/11/2012 3:13 PM

Tell a friend about this page
Print version

A Swedish cross-cultural … - University of Gothenburg, Sweden Till startsida
Sitemap
To content Read more about how we use cookies on gu.se

A Swedish cross-cultural adaptation and validation of the Tinnitus Functional Index

Journal article
Authors Maria Hoff
Kim R. Kähäri
Published in International Journal of Audiology
Volume 56
Pages 277-285
ISSN 1499-2027
Publication year 2017
Published at Institute of Neuroscience and Physiology, Department of Health and Rehabilitation
Pages 277-285
Language en
Links dx.doi.org/10.1080/14992027.2016.12...
Keywords behavioural measures, instrumentation, psycho-social/emotional, Tinnitus
Subject categories Other Medical Sciences

Abstract

© 2016 British Society of Audiology, International Society of Audiology, and Nordic Audiological Society.Objective: The Tinnitus Functional Index (TFI) is a recent self-report instrument for tinnitus with potential advantages over other existing instruments, including a demonstrated high responsiveness. The objectives of this study were to translate and cross-culturally adapt the TFI into Swedish and to investigate its validity and reliability. Design: The development of the Swedish version (TFI-SE) followed published guidelines on cross-cultural adaptation of health questionnaires. Validity and reliability was investigated by correlating responses on the TFI-SE with other tinnitus measures [Tinnitus Handicap Inventory (THI) and visual analogue scale (VAS)] and a scale measuring anxiety and depression (HADS). Study sample: Consecutively recruited tinnitus patients (n = 100) from four Swedish clinics completed the questionnaires. The mean age of the sample was 51 years (SD =17). Results: The internal consistency of the TFI-SE was good (α = 0.95) and the test–retest reliability was high (ICC =0.93). Our results supported the eight-factor structure proposed for the original TFI, and a high correlation between the TFI-SE and the THI (r = 0.8; p < 0.01) and lower correlations between the TFI-SE and the HADS-D (r = 0.60; p < 0.01) and HADS-A (r = 0.59; p < 0.01) confirmed satisfactory convergent and discriminant validity. Conclusions: We found that the Swedish translation and cross-cultural adaptation of the TFI is valid and reliable for use with adult tinnitus patients.

Page Manager: Webmaster|Last update: 9/11/2012
Share:

The University of Gothenburg uses cookies to provide you with the best possible user experience. By continuing on this website, you approve of our use of cookies.  What are cookies?

Denna text är utskriven från följande webbsida:
http://www.gu.se/english/research/publication/?publicationId=253360
Utskriftsdatum: 2019-09-16