To the top

Page Manager: Webmaster
Last update: 9/11/2012 3:13 PM

Tell a friend about this page
Print version

Subcrestal placement of t… - University of Gothenburg, Sweden Till startsida
Sitemap
To content Read more about how we use cookies on gu.se

Subcrestal placement of two-part implants

Journal article
Authors Maria Welander
Ingemar Abrahamsson
Tord Berglundh
Published in CLINICAL ORAL IMPLANTS RESEARCH
Volume 20
Issue 3
Pages 226-231
ISSN 0905-7161
Publication year 2009
Published at Institute of Odontology
Pages 226-231
Language en
Links dx.doi.org/10.1111/j.1600-0501.2008...
Keywords bone-formation adjacent, titanium implants, crestal bone, soft-tissues, histometric evaluation, submerged implants, biologic width, canine mandible/, dogs, surface
Subject categories Industrial Biotechnology, Dentistry

Abstract

OBJECTIVE: The aim of the present experiment was to study the healing around two-part implants that were placed in a subcrestal position. MATERIAL AND METHODS: Five mongrel dogs, about 2 years old, were included. The mandibular premolars and the first, second and third maxillary premolars were extracted. Three months later two test and two control implants (OsseoSpeed, 3.5 mm x 8 mm) were placed in one side of the mandible. The implants were placed in such a way that the implant margin was located 2 mm apical to the bone crest. In the test implants, the surface modification extended to the implant margin and, thus, included the shoulder part of the implant. Regular abutments with a turned surface (Zebra) were connected to the control implants, while experimental abutments with a modified surface (TiOblast) were connected to the test implants. A plaque control program that included cleaning of implants and teeth every second day was initiated. Four months later the dogs were euthanized and biopsies were obtained and prepared for histological analysis. RESULTS: The marginal bone level at the test implants was identified in a more coronal position than that at the control implants. In 40% of the test implants, the bone-to-implant contact extended coronal of the abutment/fixture (A/F) border, i.e. in contact with the abutment part of the implant. The connective tissue portion of the peri-implant mucosa that was facing the test abutments contained a higher density of collagen and a smaller proportion of fibroblasts than that at the control sites. CONCLUSION: It is suggested that osseointegration may occur coronal to the A/F interface of two-part implants. Such a result, however, appears to depend on the surface characteristics of the implant components.

Page Manager: Webmaster|Last update: 9/11/2012
Share:

The University of Gothenburg uses cookies to provide you with the best possible user experience. By continuing on this website, you approve of our use of cookies.  What are cookies?

Denna text är utskriven från följande webbsida:
http://www.gu.se/english/research/publication/?publicationId=123968
Utskriftsdatum: 2019-10-13