To the top

Page Manager: Webmaster
Last update: 9/11/2012 3:13 PM

Tell a friend about this page
Print version

The relationship between … - University of Gothenburg, Sweden Till startsida
Sitemap
To content Read more about how we use cookies on gu.se

The relationship between measures of physical performance in preoperative oesophageal cancer patients

Journal article
Authors F. Eriksson
U. Trölle
Suada Becovic
M. Hermansson
Monika Fagevik Olsén
Published in European Journal of Physiotherapy
ISSN 2167-9169
Publication year 2019
Published at Institute of Neuroscience and Physiology
Institute of Clinical Sciences, Department of Gastrosurgical Research and Education
Language en
Links dx.doi.org/10.1080/21679169.2019.16...
Subject categories Cancer and Oncology, Other Medical Sciences

Abstract

Background and aim: Preoperative testing of physical performance is common for patients undergoing an esophagectomy, but little evidence exists suggesting which measures are most suitable. This study compared outcome measures currently used at participating hospitals (spirometry, cycle ergometer test) against other validated tests–Maximal Inspiratory Pressure (MIP), Maximal Expiratory Pressure (MEP), Timed Up and Go (TUG), 6 Minute Walk Test (6MWT), heel raise test, shoulder abduction test, Timed Stands Test (TST) and handgrip strength. Methods: 109 patients were recruited from three university hospitals in Sweden. Participants were tested using a protocol testing respiratory and peripheral muscle strength, lung function, endurance and fitness. Results: There were strong correlations between the cycle ergometer and grip strength (r = 0.619), 6MWT (r = 0.572), MIP (r = 0.619) and MEP (r = 0.529). A strong correlation was also seen between spirometry and grip strength (r = 0.508–0.574). A moderate correlation was found between spirometry, MIP (r = 0.405–0.470) and MEP (r = 0.366–0.452), the cycle ergometer, TUG (r = −0.321) and TST (r = −0.308) and between 6MWT and PEF (r = −0.333). Conclusion: The strong correlations between different measures suggest that in cases where the standard tests are inadvisable or impractical, simple tests like grip strength and 6MWT could be used instead. © 2019, © 2019 Informa UK Limited, trading as Taylor & Francis Group.

Page Manager: Webmaster|Last update: 9/11/2012
Share:

The University of Gothenburg uses cookies to provide you with the best possible user experience. By continuing on this website, you approve of our use of cookies.  What are cookies?