Light-curing units used in dentistry: factors associated with heat development-potential risk for patients

Journal article
Authors M. Mouhat
J. Mercer
L. Stangvaltaite
Ulf Örtengren
Published in Clinical Oral Investigations
Volume 21
Issue 5
Pages 1687-1696
ISSN 1432-6981
Publication year 2017
Published at Institute of Odontology
Pages 1687-1696
Language English
Links doi.org/10.1007/s00784-016-1962-5
Keywords Dentistry, Curing lights, Tooth, Light, Temperature, pulp chamber temperature, in-vitro, resin-composites, dental resins, polymerization, irradiance, increase, intensity, exposure, exotherm, Dentistry, Oral Surgery & Medicine
Subject categories Dentistry

Abstract

To investigate how heat development in the pulp chamber and coronal surface of natural teeth with and without cusps subjected to irradiance using light-emitting diode (LED)-light-curing units (LCUs) is associated with (i) irradiance, (ii) time, (iii) distance, and (iv) radiant exposure. Three different LED-LCUs were used. Their irradiance was measured with a calibrated spectrometer (BlueLight Analytics Inc., Halifax, Canada). An experimental rig was constructed to control the thermal environment of the teeth. The LED-LCU tip position was accurately controlled by a gantry system. Tooth surface temperature was measured by thermography (ThermaCAM S65 HS, FLIR Systems, Wilsonville, USA) and pulp chamber temperature with a thermocouple. LED-LCU tip distance and irradiation times tested were 0, 2, and 4 mm and 10, 20, and 30 s, respectively. Ethical permission was not required for the use of extracted teeth. Maximum surface and pulp chamber temperatures were recorded in tooth without cusps (58.1 A degrees C +/- 0.9 A degrees C and 43.1 A degrees C +/- 0.9 A degrees C, respectively). Radiant exposure explained the largest amount of variance in temperature, being more affected by time than irradiance. At all combinations of variables tested, repeated measurements produced consistent results indicating the reliability of the method used. Increased exposure time seems to be the factor most likely to cause tissue damage. Risk of superficial tissue damage at irradiances > 1200 mW/cm(2) is evident. There is a risk of pulp damage when only thin dentin is left at higher irradiances (> 1200 mW/cm(2)). Clinicians should be aware of LED-LCU settings and possible high temperature generated.

Page Manager: Webmaster|Last update: 9/11/2012
Share:

The University of Gothenburg uses cookies to provide you with the best possible user experience. By continuing on this website, you approve of our use of cookies.  What are cookies?